Sun StorEdge L1000 User’s Guide • May 1998
Start-up Problems
describes the corrective action for problems which occur while starting up
the library.
TABLE 6-1
Start-up Problems
Problem
Corrective Action
The library does not power
on.
Be sure the library power switch is set to the | (on)
position and the power cord is connected to a grounded
electrical outlet.
The library or tape drives
do not respond on the SCSI
bus.
Be sure each SCSI device on the same SCSI bus has a
unique address and the last device is properly
terminated.
The library reports are not
ready during initialization.
Determine the failure type by checking any previous error
codes returned to the host computer. Correct the cause of
the error.
One or more tape drives fail
to spin up during start-up.
Check all SCSI cabling and termination on the back panel
of the library. If necessary, contact your field service
representative about replacing the drive(s).
The gripper has a cartridge,
preventing system
calibration and inventory.
Manually remove the cartridge from the gripper. Then,
restart the library.
The library starts up in
standby mode.
Press the Standby button. Verify the library switches to
on-line. You can use the control panel to select either on-
line or standby mode at power-up.
Содержание StorEdge L1000
Страница 16: ...xvi Sun StorEdge L1000 User s Guide May 1998 ...
Страница 18: ...xviii Sun StorEdge L1000 User s Guide May 1998 ...
Страница 58: ...36 Sun StorEdge L1000 User s Guide May 1998 ...
Страница 72: ...50 Sun StorEdge L1000 User s Guide May 1998 ...
Страница 94: ...72 Sun StorEdge L1000 User s Guide May 1998 ...
Страница 100: ...78 Sun StorEdge L1000 User s Guide May 1998 ...
Страница 104: ...82 Sun StorEdge L1000 User s Guide May 1998 ...
Страница 122: ...100 Sun StorEdge L1000 User s Guide May 1998 ...