Sun StorEdge L1000 User’s Guide • May 1998
In
, the host computer is connected to the SCSI port associated with the
library. Since there is only one SCSI bus, use all the SCSI cables from the accessories
kit to daisy-chain the library to each of the tape drives.
FIGURE 2-16
Four-Drive, Two-Bus SCSI Configuration
illustrates a two-SCSI-bus configuration. Bus 1 connects to the library
and tape drives 0 and 1 (upper drives). Bus 2 connects to tape drive 3 and 2 (lower
drives). The first SCSI bus is terminated at drive 0; the second, at drive 2.
For this configuration, you need the following items from the accessories kit:
■
Both 7-inch (18-centimeter) SCSI cables
■
15-inch (38-centimeter) SCSI cable
■
2 SCSI terminators
To host
computers
Terminators
7-inch (18-cm)
15-inch (38-cm)
Host connector
StorEdge L1000
back panel
TH000013a
SCSI cables
SCSI cable