132
Sun Fire X4500/ X4540 Servers Administration Guide • October 2008
power-on self-test
(POST)
A program that takes uninitialized system hardware and probes and tests its
components at system startup. POST configures useful components into a
coherent, initialized system and hands it over to the OpenBoot PROM. POST
passes to OpenBoot PROM a list of only those components that have been
successfully tested.
PowerPC
An embedded processor.
Q
quiesce
To halt all drive activity.
R
random-access memory
(RAM)
Volatile, semiconductor-based memory in which any byte of memory can be
accessed without touching the preceding bytes.
read-only file
A file that a user cannot modify or delete.
read-only memory
(ROM)
A nonvolatile memory chip on which data has been prerecorded. Once written
onto a ROM chip, data cannot be removed and can only be read.
read caching
Data stored for future retrieval, to reduce disk I/O as much as possible.
real-time clock (RTC)
A battery-backed component that maintains the time and date for a system,
even when the system is powered off.
reboot
An operating system-level operation that performs a system shutdown
followed by a system boot. Power is a prerequisite.
redundant array of
independent disks
(RAID)
A configuration in which multiple drives are combined into a single virtual
drive to improve performance and reliability.
reliability, availability,
and serviceability
(RAS)
A term to describe product features that include high availability, easily
serviced components, and dependability.
Содержание Fire X4540
Страница 14: ......
Страница 21: ...Chapter 1 Introduction to the Sun Fire X4500 Server 7 FIGURE 1 4 Disk Drive Locations ...
Страница 22: ...8 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 1 5 Disk Drive and Fan Tray LEDs ...
Страница 40: ...26 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 42: ...28 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 4 1 Disk Drive Locations ...
Страница 54: ...40 Sun Fire X4500 X4540 Servers Administration Guide October 2008 6 You can now remove the hard drive ...
Страница 62: ...48 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 72: ...58 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 78: ......
Страница 86: ...72 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 8 4 Disk Drive Locations ...
Страница 120: ...106 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 128: ...114 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 138: ...124 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...