44
Sun Fire X4500/ X4540 Servers Administration Guide • October 2008
fmdump
Command
The
fmdump
command displays the list of faults detected by the FMA. You can use
this command for the following reasons:
■
To see if any faults have been detected by the FMA.
■
If you need to obtain the fault message ID (SUNW-MSG-ID) for detected faults.
■
To verify that the replacement of a FRU has cleared the fault and not generated
any additional faults.
To use the
fmdump
command to identify faults:
●
Check the event log by typing the
fmdump
command with
-v
for verbose
output. For example:
The following is an example of displayed information. This example provides details
about the date, time and unique identifier related to the fault:
Diagnosing Disk Faults
To determine which disk failed, you can view the FMA fault error log, use
fmdump
command, or open the system cover to look for illuminated LEDs. If you use the
fmdump
command to isolate a disk, you should also open the system cover and look
for amber LEDs.
#
fmdump -v
CODE EXAMPLE 5-1
fmdump Command Verbose Output
TIME
UUID
SUNW-MSG-ID
Jul 11 13:55:01.5548 e92f2cec-e393-cd04-89ff-c5e2081b9940 DISK-
8000-0X
100% fault.io.disk.predictive-failure
Problem in: hc:///:serial=VDK41BT4C7MB7S:part=HITACHI-
HDS7225SBSUN250G-527N7MB7S:revision=V44OA81A/motherboard=
0/hostbridge=2/pcibus=9/pcidev=8/pcifn=0/pcibus=11/pcidev=
1/pcifn=0/sata-port=1/disk=0
Affects: hc:///:serial=VDK41BT4C7MB7S/component=sata5/1
FRU: hc:///component=HD_ID_16
Содержание Fire X4540
Страница 14: ......
Страница 21: ...Chapter 1 Introduction to the Sun Fire X4500 Server 7 FIGURE 1 4 Disk Drive Locations ...
Страница 22: ...8 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 1 5 Disk Drive and Fan Tray LEDs ...
Страница 40: ...26 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 42: ...28 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 4 1 Disk Drive Locations ...
Страница 54: ...40 Sun Fire X4500 X4540 Servers Administration Guide October 2008 6 You can now remove the hard drive ...
Страница 62: ...48 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 72: ...58 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 78: ......
Страница 86: ...72 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 8 4 Disk Drive Locations ...
Страница 120: ...106 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 128: ...114 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 138: ...124 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...