Chapter 3
Identifying and Configuring Components
23
Determining Attachment Points
The
cfgadm
command provides all resources and dynamic reconfiguration
operations in terms of a common set of states (such as configured and unconfigured)
and operations (such as connect, configure, unconfigure, and so on). For more
information about these common states and operations, see
the cfgadm
(1M)
man page.
To obtain a list of all available logical attachment points, use the following
commands in the domain.
1. Log on as a superuser.
2. Type
cfgadm -l
to display information about server attachment points.
In this example, c0 and c1 represent two SCSI controllers.
Changing to Attachment Points
Attachment points contain state and condition information. An attachment point can
be in one of five conditions: unknown, ok, failing, failed, or unusable. An attachment
point can enter the system in any condition depending upon results of power-on
tests and non-volatile record keeping.
You can use the
cfgadm
command to change attachment points.
■
To change the state of an attachment point, use these specific
cfgadm
options:
■
configure
■
unconfigure
■
connect
■
disconnect
■
To change the availability of an attachment point’s associations, use these specific
cfgadm
options:
■
assign
■
unassign
CODE EXAMPLE 3-6
cfgadm
Command Display of Attachment Point
#
cfgadm -l
Ap_Id
Type
Receptacle
Occupant
Condition
c0
scsi-bus
connected
configured
unknown
c1
scsi-bus
connected
configured
unknown
Содержание Fire X4540
Страница 14: ......
Страница 21: ...Chapter 1 Introduction to the Sun Fire X4500 Server 7 FIGURE 1 4 Disk Drive Locations ...
Страница 22: ...8 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 1 5 Disk Drive and Fan Tray LEDs ...
Страница 40: ...26 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 42: ...28 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 4 1 Disk Drive Locations ...
Страница 54: ...40 Sun Fire X4500 X4540 Servers Administration Guide October 2008 6 You can now remove the hard drive ...
Страница 62: ...48 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 72: ...58 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 78: ......
Страница 86: ...72 Sun Fire X4500 X4540 Servers Administration Guide October 2008 FIGURE 8 4 Disk Drive Locations ...
Страница 120: ...106 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 128: ...114 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Страница 138: ...124 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...