4-2
Sun Enterprise 6500/5500/4500 Systems Reference Manual • April 1998
4.1
Handling Boards and Assemblies
Caution –
The chassis AC power cord must remain connected to ensure a proper
ground.
Caution –
The I/O+ boards, their modules, and cards have surface-mount
components that can be broken by flexing the boards.
To minimize the amount of board flexing, observe the following precautions:
■
Hold the board only by the edges near the middle of the board, where the board
stiffener is located. Do not hold the board only at the ends.
■
When removing the board from an antistatic bag, keep the board vertical until
you lay it on the Sun ESD mat.
■
Do not place the board on a hard surface. Use a cushioned antistatic mat. The
board connectors and components have very thin pins that bend easily.
■
Do not use an oscilloscope probe on the components. The soldered pins are easily
damaged or shorted by the probe point.
■
Transport the board in an antistatic bag.
■
Be careful of small parts located on the component side of the board.
■
Be careful not to drag boards across surfaces as board components are easily
damaged.
Caution –
The heatsinks on the board can be damaged by incorrect handling. Do
not touch the heatsinks while installing or removing the board. Hold the board only
by the edges. If a heatsink is loose or broken, obtain a replacement board.
Caution –
When inserting the board into slot 4 or slot 10 of a 16-slot card cage, lift
the board slightly to avoid damage to the centerplane connectors.
Caution –
The heatsinks on the board can be damaged by improper packaging.
When storing or shipping the board, ensure that the heatsinks have sufficient
protection.
Содержание 5500
Страница 12: ...xii Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 20: ...xx Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 85: ...Chapter 4 I O Boards and Components 4 27 FIGURE 4 24 Graphics I O Board GBIC Connector Locations GBIC 1 GBIC 0 ...
Страница 89: ...Chapter 4 I O Boards and Components 4 31 FIGURE 4 27 PCI Card Removal Catch mechanism ...
Страница 94: ...4 36 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 128: ...7 14 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 172: ...11 10 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 184: ...12 12 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 208: ...B 20 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 272: ...F 24 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 290: ...G 18 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...