3-18
Sun Enterprise 6500/5500/4500 Systems Reference Manual • April 1998
3. Use the system error messages to locate the slot (
) for the SIMM you
need to replace.
4. Eject the faulty SIMM by pressing down on the ejection levers on both sides of
the SIMM connector (
).
FIGURE 3-13
Ejecting a SIMM
5. Holding the SIMM by its edges, remove it from the slot and place it on an
antistatic surface.
3.4.5.2
Installing a Memory Module
Requirements
All banks must have the same size SIMMs, however, SIMMs from different
manufacturers are interchangeable in a single bank if the SIMMs all have the same
capacity and speed. Sort the SIMMs into banks of eight using the same size SIMMs.
Содержание 5500
Страница 12: ...xii Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 20: ...xx Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 85: ...Chapter 4 I O Boards and Components 4 27 FIGURE 4 24 Graphics I O Board GBIC Connector Locations GBIC 1 GBIC 0 ...
Страница 89: ...Chapter 4 I O Boards and Components 4 31 FIGURE 4 27 PCI Card Removal Catch mechanism ...
Страница 94: ...4 36 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 128: ...7 14 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 172: ...11 10 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 184: ...12 12 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 208: ...B 20 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 272: ...F 24 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 290: ...G 18 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...