Chapter 3
CPU/ Boards and Components
3-15
1. Take the UltraSPARC II module out of the protective packaging and inspect for
dust on the connectors.
If necessary, clean the connectors with a dry, stiff toothbrush.
2. Remove the applicable CPU/ board as indicated in Section 3.4.1
3. Inspect the board module mating surface and connectors. If they require cleaning,
use a dry, stiff toothbrush to remove debris.
Note –
There are miniature silver alignment pins on the compression connectors
which, when the module is properly seated, align with related receptacles on the
mating surfaces of the CPU/ board. In addition, there is a gold standoff
mounted on the CPU/ board opposite the module’s smaller board
connector. This acts as a standoff for the module as well as an alignment pin.
4. Holding the module by the edges, align the module over the two board
receptacles (use the single standoff and the alignment pins on the module
compression connector as a guide). See
and
.
5. Rest the module on the board standoff, aligning the compression connectors with
the screws.
Firmly but gently press the module straight down until the standoff post snaps into
place and the module connectors are fully seated.
6. Using the torque screwdriver provided with your system, partially tighten the five
3/32 hex screws:
a. Partially tighten the screws just until they touch the compression connectors in
order, beginning with screw 1.
b. Tighten the five screws an additional one-half turn in the same tightening
sequence.
4 1 3
2
5
4 1 3
2
5
Tightening sequence
Содержание 5500
Страница 12: ...xii Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 20: ...xx Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 85: ...Chapter 4 I O Boards and Components 4 27 FIGURE 4 24 Graphics I O Board GBIC Connector Locations GBIC 1 GBIC 0 ...
Страница 89: ...Chapter 4 I O Boards and Components 4 31 FIGURE 4 27 PCI Card Removal Catch mechanism ...
Страница 94: ...4 36 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 128: ...7 14 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 172: ...11 10 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 184: ...12 12 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 208: ...B 20 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 272: ...F 24 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 290: ...G 18 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...