5-14
Sun Enterprise 6500/5500/4500 Systems Reference Manual • April 1998
8. Using the drive retainer as a handle, slide the drive in and then seat it to the board
connector receptacle.
Close and latch the ejector drive retainer.
9. SCSI IDs for disk drives on Disk boards are selected on the Disk board.
See Appendix C “SCSI Devices” to select the SCSI ID for the disk drive.
10. Check that the ejector drive retainers on both disk drives are closed, latched in
place, and do not extend past the edge of the board.
If an ejector drive retainer extends past the edge of the Disk board or is not fully
closed, the disk drive connector is not joined with the Disk board connector. Do the
following:
a. Use the unlatched drive retainer to unseat the drive from the board connector
receptacle and slide it out an inch or two.
b. Check that the connectors are not broken and that nothing blocks the joining of
these two connectors.
If there is a problem, put the disk drive back into its protective packaging, and
contact your service representative.
Note –
Save the antistatic shipping bag and other original packing. You will need
these materials when transporting the disk drive.
11. Terminate the SCSI-out connector, if necessary.
The SCSI-out connector on Disk boards that are not daisy chained to an additional
device must be terminated with a SCSI terminator. See
Note –
The last or only disk board in a system must have the SCSI out connector
terminated with a fast-wide SCSI terminator, part number 150-2267.
12. Replace the Disk board as described in Section 5.5.2 “Installing a Board.”
Содержание 5500
Страница 12: ...xii Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 20: ...xx Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 85: ...Chapter 4 I O Boards and Components 4 27 FIGURE 4 24 Graphics I O Board GBIC Connector Locations GBIC 1 GBIC 0 ...
Страница 89: ...Chapter 4 I O Boards and Components 4 31 FIGURE 4 27 PCI Card Removal Catch mechanism ...
Страница 94: ...4 36 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 128: ...7 14 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 172: ...11 10 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 184: ...12 12 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 208: ...B 20 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 272: ...F 24 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Страница 290: ...G 18 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...