Troubleshooting

The Hyponic® unit is running normally when it meets the following criteria:

1) 

The motor begins to run immediately after the start switch is moved to the ON position.

2) 

The unit does not make any abnormal sounds during operation.

3) 

The motor stops running within about 0.5 seconds after power to the unit is switched off.

Problem

Possible Cause

Corrective Action

Runs Hot

Overloading

Load exceeds the capacity of the 
Hyponic®

Check rated capacity of the Hyponic®; replace 
with unit of sufficient capacity or reduce load.

Improper 
lubrication

Wrong lubricant

Flush out and refill with correct lubricant as 
recommeded.

Vibration or 
noise

Loose
Foundation 
bolts /
Torque Arm

Weak mounting structure

Inspect mounting of Hyponic®. Tighten loose 
bolts and/or reinforce mounting structure.

Loose bolts

Tighten bolts.

Failure of 
bearings

May be due to lack of lubricant

Replace unit.

Overload

Check rated capacity of Hyponic®, replace with 
unit of sufficient capacity or reduce load.

Output shaft 
does not turn

Motor shaft 
broken

Overloading of reducer can cause 
damage

Replace broken shaft. Check rated capacity of 
Hyponic®.

Key missing or sheared off on 
input shaft

Replace key.

Motor
doesn’t turn

Motor

Refer to Motor section of Troubleshooting 
Guide.

Load is 
disconnected 
but motor 
doesn’t rotate

Makes a 
groaning 
sound

Faulty switch contact

Replace contact.

Blown fuse

Replace.

One phase wire of the power 
supply open

Replace.

Stator coil open

Repair by rewinding or replacing stator 
assembly.

Stator and rotor touching due to 
bearing housing wear

Replace the bearing and bracket.

Table 18. Quick Troubleshooting Guide

Problem

Possible Cause

Corrective Action

Load is 
disconnected 
but motor 
doesn’t rotate 
(cont.)

Starts in either 
direction when 
turned by hand

Three phase is operating as single-
phase

Check the power source with a 
voltmeter.

Doesn’t make 
any noise

Stator coil open

Repair by rewinding or replacing stator 
assembly.

Outside the 
motor

Power failure

Contact the power company. 

Open connection 
wire

Check the source wiring.

Faulty starter 
contact

Replace contact.

Rotates with 
the load 
disconnected, 
but:

Rotates in the 
wrong direction

Connection error

Change any two of the three-phase 
source.

Fuse blows

Shorted lead wire

Replace.

Speed doesn’t 
increase

Faulty starter contact

Replace contact.

Groans

Overcurrent 
Overheating

Rotor and 
stator touching

Repair by winding or replacing stator 
assembly.

Overcurrent

One phase 
of stator coil 
shorted

Replace the stator winding.

Makes a high 
pitched metallic 
noise

Faulty bearing

Replace the bearing.

Rotates 
when the 
load is dis- 
connected 
but when 
the load is 
connected:

Switch 
overheats

Insufficient switch capacity

Replace with one having the rated 
capacity.

Overload

Drop to the rated load.

Fuse blows

Insufficient fuse capacity

Replace with one having the rated 
capacity.

Overheats

Overload

Drop to the rated load.

Voltage drop

Consult with the power company.

Speed suddenly 
drops

Voltage drop

Consult with the power company.

Overload

Drop to the rated load.

Stops

Bearing damaged by overheat

Replace the bearing.

Table 18. Quick Troubleshooting Guide (cont.)

H

YPONIC®

MO

TOR

MO

TOR (c

on

t.)

Содержание Hyponic 1120

Страница 1: ...Operating and Maintenance Manual 07 020 60 002 Hyponic O M 2019 Hyponic...

Страница 2: ...plosion proof motor a technician with electrical expertise should supervise the transport installation plumbing wiring operation maintenance and inspection of the equipment otherwise explosion ignitio...

Страница 3: ...is not for immediate use please note the following points when storing it Store the product indoors in a clean dry location External Rust Prevention Rust prevention oil is applied when shipping from...

Страница 4: ...ructions for proper bolt tightening torque Important If the bolt is tightened when the fitting is not inserted uneven tightening will result causing damage to the internal bearing and other components...

Страница 5: ...nufacturer recommendation and keep tension angle perpendicular to the shaft Table 2 Flange Mount Bolt Size Flange or Foot Mount Solid Shaft Type When mounting connected equipment do not apply impact o...

Страница 6: ...causing vibration or grease leak If the effective length of driven shaft is short the key and the keyway may be damaged If the hollow shaft end face is hit with a metal hammer or the driven shaft was...

Страница 7: ...only against the unit s steel hollow bore Do not strike the reducer housing or oil seal Damage to the bearings the housing and or the seals may occur Note If the fit is tight use a jig such as the on...

Страница 8: ...9 105 2327 263 Final Torque in lb Nm 43 4 9 105 11 8 266 30 531 60 885 100 2221 251 Socket Size mm 8 10 13 17 19 24 Table 3 Shrink Disc Size and Tightening Torque Mount the torque arm on the driven ma...

Страница 9: ...rmal Brake Action 230V or 575V Brake Fig 13 b Fast Brake Action 230V Brake Fig 13 c Normal Brake Action 460V Brake Fig 13 d Fast Brake Action 460V or 575V Brake Tighten both pairs of nuts against the...

Страница 10: ...ake Action 460V or 575V Brake Wiring Connections for VFD Inverter Models FB 01A1 through FB 15E 230 460V 60Hz or 575V 60Hz VFD VFD VFD VFD VFD VFD VFD VFD a Always ground the motor terminal box or fra...

Страница 11: ...meplate voltage rating 10 3 The ambient temperature around the unit is too high Table 8 Trial Run Precautions Daily Inspection and Maintenance 1 Inspect the gearmotor daily for each of the items liste...

Страница 12: ...ed at a rate greater than the Allowable Brake Work Capacity E0 the brake performance may degrade or become inoperable 1 Also applies to wiring where brake is powered separately from the motor leads Br...

Страница 13: ...olt 16 fastens the brake shoe 8 gap adjusting shims 17 and spacer 18 onto the stationary core 1 The armature plate 4 is kept from rotation by the restraining bolt 16 but moves axially by electromagnet...

Страница 14: ...not excessively worn or gap G is normal all the mounting screws are securely tightened b Manual brake release procedure FB 1D FB 2D FB 1E FB 1HE FB 2E and FB 3E brakemotors are equipped with a one tou...

Страница 15: ...a few times to check the brake performance If no abnormalities are detected replace waterproof cover 24 waterproof seal 25 V Ring 23 fan 15 retaining ring 14 cover 13 shifting pins 5 and brake releas...

Страница 16: ...Armature 5 Shifting Pin 6 Brake Release Lever 7 Retaining Clip 8 Brake Shoe 9 Brake Lining 10 Leaf Spring 11 Hub 12 C type Retaining Ring 13 Cover 14 C type Retaining Ring 15 Fan 16 Gap Adjusting Nut...

Страница 17: ...eal 26 and waterproof cover 25 c Insert a gap gage into the space between the stationary core 1 and armature plate 4 and rotate the nut 16 at the tip of the stud bolt 19 clockwise until the gap measur...

Страница 18: ...ly open Replace Stator coil open Repair by rewinding or replacing stator assembly Stator and rotor touching due to bearing housing wear Replace the bearing and bracket Table 18 Quick Troubleshooting G...

Страница 19: ...vailable from three phase power supply Measure power supply voltage and check for defective circuit Protective device has tripped Eliminate cause and reset Damaged or burned motor winding Repair or re...

Страница 20: ...36 Hyponic Operating and Maintenance Manual Hyponic Operating and Maintenance Manual 37 www SumitomoDrive com...

Страница 21: ...38 Hyponic Operating and Maintenance Manual Hyponic Operating and Maintenance Manual 39 www SumitomoDrive com Notes Notes...

Страница 22: ...rters Japan Sumitomo Heavy Industries Ltd PowerTransmission Controls Group ThinkParkTower 1 1 Osaki 2 chome Shinagawa ku Tokyo 141 6025 Japan Tel 81 36 737 2511 Fax 81 36 866 5160 07 020 60 002 Hyponi...

Отзывы: