47
MAINTENANCE
6.2
GENERAL MAINTENANCE SAFETY
WARNING!
Never assume a compressor is safe to work on just because it is not operating. It could restart at any time.
Do not allow oil to accumulate on, in or around acoustic noise material. Immediately replace any oil-
soaked material after cleaning enclosure surface with nonflammable solvent.
Do not substitute bolts with material or markings different from the original equipment.
CAUTION!
Do not over-tighten any bolt, nut fitting, connection or spin-on filter element.
Perform repairs and maintenance only in clean, dry conditions in a well-lit and ventilated area.
Clean up any spilled oil or oil leakage and repair oil leaks as soon as they are discovered.
6.3
STOPPING FOR MAINTENANCE
The following procedures should be followed before doing any maintenance on the compressor and will not
be repeated in any of the maintenance procedures.
1.
Per Occupational Safety & health Administration (OShA) regulation 1910.147: The Control of hazardous
Energy Source (Lockout/Tagout), disconnect and lockout the main power source. Display a sign in clear
view at the main power switch stating that the compressor is being serviced.
2.
Isolate the compressor from the compressed air supply by closing a manual shutoff valve downstream
from the compressor. Display a sign in clear view at the shutoff valve that the compressor is being
serviced. be certain that a pressure relief valve is installed upstream of any isolation valve.
3.
Wait until sump pressure reading is 0 psig.
4.
Open all manual drain valves within the area to be serviced.
5.
Wait for the unit to cool before starting to service. Temperatures of 125°F (52°C) can burn skin. Some
surface temperatures exceed 250°F (121°C) when the compressor is operating and just after it is shut
down.
6.4
bOLT TORQUE GUIDELINES
6.4.1
INCH FASTENERS
INCH FASTENERS TORQUE
Size
SAE Grade 5 (ft-lb)
SAE Grade 8 (ft-lb)
Dry
Oiled
Dry
Oiled
1
⁄
4
–20
8
6
12
9
5
⁄
16
–18
17
13
25
18
3
⁄
8
–16
30
23
45
35
7
⁄
16
–14
50
35
70
55
1
⁄
2
–13
75
55
110
80
9
⁄
16
–12
110
80
150
110
5
⁄
8
–11
150
110
220
170
3
⁄
4
–10
260
200
380
280
6.4.2
BOLT TORQUE FACTORS
LUbRICANT OR PLATING
TORQUE CHANGES
Oil
Reduce torque 15% to 25%
Dry film (Teflon or moly based)
Reduce torque 50%
Dry wax (Cetyl alcohol)
Reduce torque 50%
Chrome plating
No change
Cadmium plating
Reduce torque 25%
Zinc plating
Reduce torque 15%
6.4.3
BOLT TORQUE STAGES
STAGE
TORQUE
1st
20-25 ft/lbs
2nd
55-60 ft/lbs
3rd
85-95 ft/lbs
Содержание UD Series
Страница 6: ...vi About This Manual ...
Страница 12: ...4 Introduction ...
Страница 24: ...16 Specifications 2 2 DIMENSIONS OPEN AIR COOLED 230V Figure 2 1 GA 30 40 50UD AC VFD 230V R00 ...
Страница 25: ...17 Specifications 2 3 DIMENSIONS OPEN AIR COOLED 460V Figure 2 2 GA 30 40 50UD AC MPC VFD OPEN 460V R00 ...
Страница 26: ...18 Specifications 2 4 DIMENSIONS ENCLOSED AIR COOLED 460V Figure 2 3 GA 40 50 60UDAC ENC S1 R00 ...
Страница 27: ...19 Specifications 2 5 DIMENSIONS ENCLOSED HEAVY DUTY INLET OPTION 460V Figure 2 4 GA 40 50 60UDAC VFD ENC R00 ...
Страница 28: ...20 Specifications 2 6 DIMENSIONS ENCLOSED AIR COOLED HD INLET NO BUSSEL Figure 2 5 GA 60UDAC ENC VFD NB R00 ...
Страница 29: ...21 Specifications 2 7 PIPING AND INSTRUMENTATION AIR COOLED Figure 2 6 P I 15 40D AC MPC VFD R02 ...
Страница 42: ...34 Component Description ...
Страница 52: ...44 Operation ...
Страница 66: ...58 Troubleshooting ...
Страница 74: ...66 Parts Catalog 8 5 COMPRESSOR FRAME AND DRIVE ASSEMBLY Figure 8 1 AS801 25UD 50UD VFD R00 ...
Страница 76: ...68 Parts Catalog 8 6 CONTROL ASSEMBLY OPEN Figure 8 2 1072190415 609 R00 ...
Страница 78: ...70 Parts Catalog 8 7 STARTER ASSEMBLY ENCLOSED Figure 8 3 AS802 405060 PANEL R03 ...
Страница 80: ...72 Parts Catalog 8 8 AIR INLET ASSEMBLY 15 30HP 13 12 11 13 12 4 5 2 3 14 1 Figure 8 4 AS805 030D7H TE R00 ...
Страница 94: ...86 Parts Catalog 8 15 COOLING ASSEMBLY AIR COOLED Figure 8 11 AS804 50UDAC INLINE R00 ...
Страница 100: ...NOTES ...
Страница 101: ...NOTES ...