MAINTENANCE
6.9
AIR FILTER
The air filter should be replaced every 1,000 hours or more often in severe or outside conditions
or if fault
A:2030 or A:4804 is shown on the microprocessor.
The inlet filter is a critical filter, protecting the compressor from exterior foreign materials. Keeping the inlet
filter element clean will help maintain proper capacity rating of the compressor.
FIGURE 6-6.
tooltip
Filter Body
Secondary Filter Element
Primary Filter Element
End Cap
AIR FILTER MAINTENANCE
6.9.1
REMOVAL
1.
2.
Unfasten the clamps on the rear housing and remove.
3.
Remove primary air filter element and secondary filter element (if equipped).
4.
Discard the dirty air filter elements. Normal trash pickup is acceptable. Never burn.
6.9.2
INSTALLATION
1.
Attach new air filter element(s).
2.
Re-attach rear housing and secure clamps.
6.10
OIL/AFTER COOLER
The oil/after cooler fins should be inspected and cleaned every 1,000 hours (or quarterly).
6.10.1
INSPECTION
1.
Inspect the cooler from the fan guard side. If any dirt or foreign material is found, the cooler should be
removed and cleaned.
2.
Cleaning in place may cause damage to the fan or cooler.
6.10.2
REMOVAL
1.
procedures.
2.
Remove the oil/after cooler.
6.10.3
CLEANING
blow dirt and foreign material from the cooler.
6.10.4
INSTALLATION
1.
Reattach all oil tubing and air tubing to the oil/after cooler.
2.
Start compressor according to
procedures and check for leaks.
6.11
MINIMUM PRESSURE VALVE
The minimum pressure valve should be inspected and cleaned once a year, or when the separator element is
replaced. Rebuild or replace as necessary.
Содержание UD Series
Страница 6: ...vi About This Manual ...
Страница 12: ...4 Introduction ...
Страница 24: ...16 Specifications 2 2 DIMENSIONS OPEN AIR COOLED 230V Figure 2 1 GA 30 40 50UD AC VFD 230V R00 ...
Страница 25: ...17 Specifications 2 3 DIMENSIONS OPEN AIR COOLED 460V Figure 2 2 GA 30 40 50UD AC MPC VFD OPEN 460V R00 ...
Страница 26: ...18 Specifications 2 4 DIMENSIONS ENCLOSED AIR COOLED 460V Figure 2 3 GA 40 50 60UDAC ENC S1 R00 ...
Страница 27: ...19 Specifications 2 5 DIMENSIONS ENCLOSED HEAVY DUTY INLET OPTION 460V Figure 2 4 GA 40 50 60UDAC VFD ENC R00 ...
Страница 28: ...20 Specifications 2 6 DIMENSIONS ENCLOSED AIR COOLED HD INLET NO BUSSEL Figure 2 5 GA 60UDAC ENC VFD NB R00 ...
Страница 29: ...21 Specifications 2 7 PIPING AND INSTRUMENTATION AIR COOLED Figure 2 6 P I 15 40D AC MPC VFD R02 ...
Страница 42: ...34 Component Description ...
Страница 52: ...44 Operation ...
Страница 66: ...58 Troubleshooting ...
Страница 74: ...66 Parts Catalog 8 5 COMPRESSOR FRAME AND DRIVE ASSEMBLY Figure 8 1 AS801 25UD 50UD VFD R00 ...
Страница 76: ...68 Parts Catalog 8 6 CONTROL ASSEMBLY OPEN Figure 8 2 1072190415 609 R00 ...
Страница 78: ...70 Parts Catalog 8 7 STARTER ASSEMBLY ENCLOSED Figure 8 3 AS802 405060 PANEL R03 ...
Страница 80: ...72 Parts Catalog 8 8 AIR INLET ASSEMBLY 15 30HP 13 12 11 13 12 4 5 2 3 14 1 Figure 8 4 AS805 030D7H TE R00 ...
Страница 94: ...86 Parts Catalog 8 15 COOLING ASSEMBLY AIR COOLED Figure 8 11 AS804 50UDAC INLINE R00 ...
Страница 100: ...NOTES ...
Страница 101: ...NOTES ...