IAGNOSTIC PROCEDURES
Diag -2
N
AME
:
T
RAINING DEPARTMENT
D
ATE
:
04/2018
P
AGE
:
103/109
REFERENCE:
TECHNICIAN’S
OPERATING
MANUAL
POLYVRAC
XT
VISION
I
ND
02
2-
T
HE RATE ACTUATORS DO NOT MOVE
The rate actuators do not
move
Are one or both at fault?
Only 1 actuator
Check the actuator setup
(V SHUT and V OPEN)
(file B3.2)
Reverse the connection
between the two
actuators
(file B3.1)
The actuator at fault is
still not operating
Check that the actuator
cables are in good
condition
Electric actuator
repla Actuator
calibration
(file B3)
Phenomenon reversal.
The opposite side is no
longer operating
Check the DBP
connection unit wiring
(A files)
DPB connection unit
replacement
Check the intermediate
wiring
(A files)
Read the values on the
Vision console and
perform a RESET
(D files)
The 2 actuators are at
fault
Make sure that the direct
battery supply is
con fuse
(file B1)
Check the working width
programming
Check the factor 'T'
Check the actuator setup
(V SHUT and V OPEN)
(file B3.2)
Read the values on the
Vision console and
perform a RESET
(D files)