![Sulky Polyvrac XT 100 VISION Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/sulky/polyvrac-xt-100-vision/polyvrac-xt-100-vision_technicians-operating-manual_1390245090.webp)
XT
-
VISION
C
ONFIGURING THE
V
ISION
XT
P
OLYVRAC CONSOLE
D4.2
N
AME
:
T
RAINING DEPARTMENT
D
ATE
:
04/2018
P
AGE
:
90/109
REFERENCE:
TECHNICIAN’S
OPERATING
MANUAL
POLYVRAC
XT
VISION
I
ND
02
e)
Alarm setup:
Access the
SETUP
menu by pressing
.
Then press
1. Sensor configuration
Enter the PIN code:
1936
and
Indicate the
Max. Weight:
value using the number pad and
validate.
Check the other values
Press
ESC
.
Only for the SWPB weighing option
f)
SWPB weighing option:
From the Sensor configuration menu, press
Enter the PIN code: 1936 and
In the
Function:
line, display
Weighing
instead of
Not used
using
the
keys.
In the
Axles:
line, indicate the type
Check the
Min. Weight:
value
0.250 t
In the
WEIGHT RESOLUTION
line, enter
50 kg
If the conditions allow, calibrate an angle sensor. (Spreader coupled
and on flat ground): Select
Angle sensor
and validate, then press
the
key.
Press
ESC
to exit
Select
CAL FACTORS
and validate
Use the number pad to mark the calibration values for each channel
(boom, axle 1 and axle 2) Use the
key to change channel
In the case of a spreader with Tandem axles, also read the
Ratio
value
Press
ESC
3 times
The console has 3 user modes related to the spreading systems. The mode is selected when the console starts
up.