![Sulky Polyvrac XT 100 VISION Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/sulky/polyvrac-xt-100-vision/polyvrac-xt-100-vision_technicians-operating-manual_1390245092.webp)
XT
-
VISION
C
ONFIGURING THE
V
ISION
XT
P
OLYVRAC CONSOLE
D4.4
N
AME
:
T
RAINING DEPARTMENT
D
ATE
:
04/2018
P
AGE
:
92/109
REFERENCE:
TECHNICIAN’S
OPERATING
MANUAL
POLYVRAC
XT
VISION
I
ND
02
Only for the AUTO boom valve option (RD3)
l)
AUTO boom valve acutator option
From the
Actuators
page, display
Channel: 3.0
with
In the
Function:
line, display
Actuator
using
if the
machine is equipped with AUTO boom valves (RD3)
(If the spreader does not have AUTO boom valves AUTO (RD2) leave
Not used)
Check
Deadband: 0.10
and
Actuator length: 100
Go down to
V SHUT
then
V OPEN
and enter the respective values
before validating.
Go back up to
Channel:
and display the
Channel:
page
4.0
by pressing
Repeat the operations on Channel 4
Press
ESC
2 times
m)
Gate setup:
Access the
SETUP
menu by pressing
. Then select
3. Factory
config
Enter the PIN code: "
0035"
and validate with
Press
1. Machine options
Enter the values:
1.GATE WIDTH 0.80
2.REDUCER COEFF 0.50
3.PI 25.0
4.Pq -50
The "
-" symbol is obtained by pressing
Press
ESC
to exit