XT
-
VISION
W
EIGHING SENSOR
B10.2
N
AME
:
T
RAINING DEPARTMENT
D
ATE
:
04/2018
P
AGE
:
63/109
REFERENCE:
TECHNICIAN’S
OPERATING
MANUAL
POLYVRAC
XT
VISION
I
ND
02
Diagnostic on the console:
Access the
SETUP
page with the
key
Press
for
"Diagnostics"
Select
With the spreader empty, position the tractor/spreader assembly in a
straight line, without reversing and without applying the brake, on flat
ground.
The voltage of the different sensors ① unladen must be close to 4.00
V.
(If this is not the case, check the connection from the sensor at fault
to the CAN module. Disconnected sensor = 0V. If the connections are ok,
replace the sensor and adjust the offsets)
Under load, the voltage on the different sensors must fall
Inspection in the CAN module connection unit:
a)
Sensor power supply check:
Measure the voltage between the red wire and the black wire
on each sensor => +12 V
b)
Sensor signal check:
Measure the voltage on the white wire and the black wire of
each sensor => The voltages must be thise indicated in the
console's
"Diagnostics"
menu. (Close to 4.00 V unloaded)
Replacing a weighing sensor requires specific equipment to adjust the sensor's OFFSET. See File B12