Page 24
used to connect to the unit to permit the unit to communcate with the printer and bar code read-
er.. Additionally, if both a printer and a bar code reader are to be used with the unit, both will
need to communicate at the same baud rate.
To make the Serial Printer function active, press the
Enter button when this function is displayed.
A new display will open providing the option of leaving
the function off or selecting a baud rate. To make the
function active, use the Up and Down buttons to scroll
to the baud rate that will be used to communicate with
the printer.
Press the Enter button to store the new selection or
press the Esc button to exit this setting without storing
a new value.
Bar Code Reader
The Atlas Copco Open Protocol allows much more than the torque data to be reported across
the ethernet, and some assembly operations desire to have such additional descriptive informa-
tion. The TCV Ethernet eases the tasks associated with this by allowing the use of a bar code
reader.
A serial bar code reader can be connected to the TCV-Ethernet unit to ease data input tasks for
programming, as well.
There is only one serial port on the unit, so a Y-cable must be used if the bar code reader is to
be used in tandem with a serial printer.
The front panel programming items that can be filled in via a bar code reader and bar code dur-
ing programming are:
Cell ID
Channel ID
Control Name
Batch Reset
TCV Timer Min*
TCV Timer Max*
The following values to describe torque data more completely or to tie data to specific assem-
blies or specifications can be modified or have data entered via the bar code reader:
VIN Batch Size
Tool Serial Number
Job Number
Torque Min Limit
Torque Max Limit
Torque Final Target
Angle Min*
Angle Max*
Angle Final Target
Job Sequence Number
Parameter Set Name