Expert 14001 Battery charge current (VS-120)
120 Adc
Basic
14002 Configuration of PV modules (VS-120)
Automatic
Expert 14005 Floating voltage
54.4 Vdc
Expert 14006 Force phase of floating
-
Expert 14008 Absorption phase allowed
Yes
Expert 14009 Absorption voltage
57.6 Vdc
Expert 14010 Force absorption phase
-
Expert 14011 Absorption duration
120 min
Expert 14012 End of absorption triggered by the current
No
Expert 14013 Current threshold to end absorption phase
10 Adc
Expert 14017 Equalization allowed
No
Expert 14018 Force equalization
-
Expert 14019 Equalization before absorption phase
Yes
Expert 14020 Equalization current
80 Adc
Expert 14021 Equalization voltage
62.4 Vdc
Expert 14022 Equalization duration
30 min
Expert 14023 Equalization with fixed interval
Yes
Expert 14024 Days between equalizations
26 days
Expert 14025 End of equalization triggered by the current
No
Expert 14026 Current threshold to end equalization phase
10 Adc
Expert 14028 Force a new cycle
-
Expert 14029 Voltage level 1 to start a new cycle
48.8 Vdc
Expert 14030 Time period under voltage level 1 to start a new cycle
30 min
Expert 14031 Voltage level 2 to start a new cycle
47.2 Vdc
Expert 14032 Time period under voltage level 2 to start a new cycle
2 min
Expert 14033 Cycling restricted
Yes
Expert 14034 Minimal delay between cycles
1 hours
Expert 14035 Temperature compensation
-3 mV/°C/cell
Basic
14036 Synchronisation battery cycle with Xtender
Yes
Expert 14038 ON of the VarioString
-
Expert 14039 OFF of the VarioString
-
Expert 14040 Type of battery grounding
No control
Expert 14041 Type of PV grounding
No control
Expert 14042 Type of PV2 grounding
No control
Expert 14043 Type of MPP tracking algorithm PV
LSF
Expert 14044 PV voltage fixed (for PV in series)
700 Vdc
Expert 14045 Ratio of PV open circuit voltage
0.7
Expert 14046 Type of MPP tracking algorithm PV2
LSF
Expert 14047 PV2 voltage fixed
500 Vdc
Expert 14048 Ratio of PV2 open circuit voltage
0.7
Expert 14051 Reset daily solar production meters
-
Expert 14052 Reset daily min-max
-
Expert 14059 Reset of all VarioString
-
Basic
14067 Restore default settings
-
Inst.
14068 Restore factory settings
-
Inst.
14069 Parameters saved in flash memory
Yes
Expert 14071 Operating mode (AUX 1)
Automatic
Содержание VarioString VS-120
Страница 2: ...Studer Innotec SA VarioString 2 V 2 3 User manual ...
Страница 13: ...Studer Innotec SA VarioString User manual V 2 3 13 4 1 2 VarioString VS 120 ...
Страница 61: ...Studer Innotec SA VarioString User manual V 2 3 61 ...
Страница 62: ...Studer Innotec SA VarioString 62 V 2 3 User manual ...
Страница 63: ...Studer Innotec SA VarioString User manual V 2 3 63 ...