TECHNICAL DATA S-WG WATER HEATERS
GENERAL
Product Identification number
CE 0063 BR3190
Classification
II2H3P
Gas Appliance Type
B23; B23P; C13X, C23X, C33X, C43X, C53X, C63X, C83X
Type water heater
S-WG80
S-WG100
S-WG120
S-WG150
S-WG180
Dimensions (h x w x d)
mm
842 x 476 x 486
898 x 476 x 677
Water content est.
Litre
5.0
6.5
8.3
10.4
12.9
Weight dry
kg
68
73
78
87
96
In- and outlet water connection union
inch
1½
2
2
2
2
Gas connection
inch
R ¾
R ¾
R ¾
R 1
R 1
Flue duct flue/air inlet
mm
80/125
100/150
100/150
100/150
100/150
Parallel connection
mm
80-80
100-100
100-100
130-130
130-130
DOMESTIC HOT WATER
Nominal input min./max. (Net)
kW
14.6 - 74.3
17.2 - 92.2
26.0 - 111
34.0 - 138
45.0 - 166
Nominal input min./max. (gross) (G20 G25)
kW
16.2 - 82.5
19.1 - 102
28.9 - 123
37.8 - 153
50.0 - 184
Nominal input min./max. (gross) (G31)
kW
15.9 - 80.8
18.7 - 100
28.3 - 121
37.0 - 150
48.9 - 180
Nominal input min./max. (gross) (G30)
kW
15.8 - 80.2
18.6
– 99.7
34.7 - 120
36.8 - 150
48.8 - 180
Nom. output 80/60 at 100%
kW
14.0 - 71.2
16.5 - 88.4
24.7 - 106
32.6 - 132
43.3 - 180
Nom. output 50/30 at 100%
kW
15.2 - 77.5
18.0 - 96.2
27.2 - 116
35.5 - 144
47.3 - 160
Nom. output 37/30 at 30%
kW
15.7 - 80.1
18.6 - 99.5
28.1 - 120
36.7 - 149
48.5 - 175
Efficiency 40/30ºC DIN 4702-8
%
up to 110.6 % within the S-WG range
GAS CONSUMPTION
[EN437]
Natural gas
G25 min - max
m³
st
/h
1.80 - 9.14
2.12 - 11.35
3.20 - 13.66
4.18 - 16.98
5.54 - 20.43
Natural gas
G20 min - max
m³
st
/h
1.54 - 7.86
1.82 - 9.76
2.75 - 11.75
3.60 - 14.60
4.76 - 17.57
Propane gas G31 min - max
m³
st
/h
0.60 - 3.04
0.70 - 3.77
1.06 - 4.54
1.39 - 5.65
1.84 - 6.79
Butane gas
G30 min - max
1
(B/P)
m³
st
/h
0.45 - 2.29
0.53 - 2.85
0.99 - 3.44
1.05 - 4.28
1.40 - 5.15
Gas supply pressure nom. G25
2
mbar
25
Gas supply pressure nom. G20
2
mbar
20
Gas supply pressure nom. G31
2
mbar
30/37
Gas supply pressure nom. G30
2
mbar
50
EMISSION
CO
2
flue gas G25/G20 min - max
3
%
8.7 - 9.0
8.7 - 9.0
8.7 - 9.0
8.7 - 9.0
8.7 - 9.0
CO
2
flue gas G31 min - max
3
%
9.3 - 10.3
9.3 - 10.3
9.3 - 10.3
9.3 - 10.4
9.3 - 10.5
CO
2
flue gas G30 min - max
3
%
9.3 - 10.4
9.3 - 10.4
9.3 - 10.4
9.3 - 10.5
9.3 - 10.6
NOx emission at 0% O
2
max.80/60
4
ppm
32.2
32.2
37.8
32.2
34.3
NOx emission at 0% O
2
max.80/60
4
mg/kWh
57.9
57.9
67.9
57.9
61.9
NOx - class [EN483 / EN15420]
-
5
Temperature flue gas estimated
@ combustion air temp 20ºC
°C
85-95
Available pressure for the flue system
5
Pa
200
INSTALLATION
Max. water temperature
°C
75
Pressure WW-system min./max.
bar
1.0-6.0
Hydraulic resistance of the water heater at
T = 17 K between in- and outlet
Head
mWC
5.8
4.7
4.1
6.0
5.5
ELECTRIC
Power consumption
W
170
170
190
250
250
Power supply
V / Hz
230 / 50
Protection class
IPX4D
NOTES
1
Using propane G31 or butane G30, maximum fan
speed needs to be reduced (parameter P4BD).
2
Below a table is given in which the min. and max.
gas supply pressures are mentioned acc. to EN437.
p nominal
[mbar]
p min
[mbar]
p max
[mbar]
G25
25
20
30
G20
20
17
25
G31
30
25
35
37
25
45
G30
50
43
57
3
CO
2
of the unit measured/set without the water heater
door in place.
4
Emissions measured during unit certification.
5
Maximum combined resistance of flue gas and air supply
piping at high fire.
Содержание S-WG 100
Страница 13: ...E09 012 246 Manual S WG 14 3 3 S WG tanks 300 Ltr 450 Ltr ...
Страница 14: ...E09 012 246 Manual S WG 15 750 Ltr ...
Страница 33: ...E09 012 246 Manual S WG 34 7 4 Electrical schematics ...
Страница 34: ...E09 012 246 Manual S WG 35 ...
Страница 39: ...E09 012 246 Manual S WG 40 For large capacity installations more than two water heaters consult STREBEL ...
Страница 122: ...E09 012 246 Manual S WG 123 notes ...
Страница 123: ...E09 012 246 Manual S WG 124 notes ...
Страница 124: ......