E09.012.246 Manual S-WG
62
SCREEN: 11
C a s c D e s i g n
0
0 = MASTER, 1 ..... 11 = SLAVES
C a s I n f
0 1 2 3 4 5 6 7 8 9 A B
Displays number, priority and state of cascade water heaters.
DESCRIPTION "CASCINFO" Screen 11
Shows the number of water heaters connected with the cascade. The master/lead water heater is designated as
0. Slave/lag water heaters will be designated 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B. When a “-“ is used instead of a num-
ber, then that water heater is either not connected, or in a lockout mode and not available for the cascade. When
an “x“ is used instead of a number, then that water heater is connected, but in lockout mode.
When the number is flashing, then that water heater is providing heat to the cascade. When the leading water
heater is changed according to the set priority change time, then that water heater’s address will be shown first in
the row of numbers.
Example 1: "3 4 5 - - - - - - 0 1 2"
There are six water heaters present and nr. 3 has priority.
Example 2: "3 4 x - - - - - - 0 1 2"
There are six water heaters present and nr. 3 has priority. Water heater 5 is present, but in a lock-out.
SCREEN: 12
C a s c P o w e r 9 9 9 % 9 9 9 %
% heat demand of total (cascade) power available (%).
D u a l
B u r n e r :
N o
One heat exchanger equipped with two burners: "Yes" or
"No".
SCREEN: 13
M a x T h e r m
O p e n
Status of the maximum thermostat: "Open" or "Closed".
G e n B l o c k
C l o s e d
Status of the general blocking contact: "Open" or "Closed".
SCREEN: 14
S i p h o n p r e s s
C l o s e d
Status of the siphon pressure switch: "Open" or "Closed".
N R V C o n t a c t
O p e n
Status of the non-return valve contact: "Open" or "Closed".
Содержание S-WG 100
Страница 13: ...E09 012 246 Manual S WG 14 3 3 S WG tanks 300 Ltr 450 Ltr ...
Страница 14: ...E09 012 246 Manual S WG 15 750 Ltr ...
Страница 33: ...E09 012 246 Manual S WG 34 7 4 Electrical schematics ...
Страница 34: ...E09 012 246 Manual S WG 35 ...
Страница 39: ...E09 012 246 Manual S WG 40 For large capacity installations more than two water heaters consult STREBEL ...
Страница 122: ...E09 012 246 Manual S WG 123 notes ...
Страница 123: ...E09 012 246 Manual S WG 124 notes ...
Страница 124: ......