E09.012.246 Manual S-WG
84
10.16 Fault codes display
The following graphs describe the lock out codes of the water heater. A lock out code can only be removed by a
manual reset of the water heater. NOTICE: Before resetting the water heater always check the water heater,
DHW system and all components corresponding to the related lock out description. Never just reset the water
heater, before analysing the possible cause of failure.
10.16.1
L
OCK
-
OUT CODES
Having a lockout means that the water heater needs a manual reset to start operating again.
When the water heater is in lockout the backlight of the display is blinking on and off.
Explanation >
9 9 9 , 5 : h r s
= time elapsed after fault & message.
Explanation >
P u m p 1
o n
= status of the pump during fault.
Display message
F0
F l o w
s e n s o r
e r r o r
p u m p
o n
9 9 9 , 5
h r s
Reason
Flow sensor not detected by the water heater caused by faulty connection/sensor.
Display message
F1
F l o w
h i g h
T e m p
p u m p
o n
9 9 9 , 5
h r s
Reason
Flow temperature exceeds the limit which has been set in the parameters.
Display message
F1
R e t u r n
h i g h
T e m p
p u m p
o n
9 9 9 , 5
h r s
Reason
The maximum return temperature as set in the parameters is exceeded.
Display message
F2
L a c k
o f
w a t e
r
p u m p
o n
9 9 9 , 5
h r s
Reason
The general required gradient water lack has failed.
Display message
F3
R e t u r n
s e n s o r
e r r o r
p u m p
o n
9 9 9 , 5
h r s
Reason
Return sensor not detected by the water heater caused by faulty connection / sensor.
Display message
F5
N o n
R e t u r n
V a l v e
p u m p
o n
9 9 9 , 5
h r s
Reason
Contact signal of the non-return valve failed.
Display message
F6
F l u e
s e n s o r
e r r o r
p u m p
o n
9 9 9 , 5
h r s
Reason
Flue gas sensor not detected by the water heater caused by faulty connection / sensor.
Display message
F7
F l u e
t e m p
t o o
h i g h
p u m p
o n
9 9 9 , 5
h r s
Reason
Flue gas temperature exceeds the limit which has been set in the parameters.
Display message
F8
F a i
l e d
b u r n e r
s t a r
t
p u m p
o n
9 9 9 , 5
h r s
Reason
Water heater is not starting after the programmed starting attempts.
Содержание S-WG 100
Страница 13: ...E09 012 246 Manual S WG 14 3 3 S WG tanks 300 Ltr 450 Ltr ...
Страница 14: ...E09 012 246 Manual S WG 15 750 Ltr ...
Страница 33: ...E09 012 246 Manual S WG 34 7 4 Electrical schematics ...
Страница 34: ...E09 012 246 Manual S WG 35 ...
Страница 39: ...E09 012 246 Manual S WG 40 For large capacity installations more than two water heaters consult STREBEL ...
Страница 122: ...E09 012 246 Manual S WG 123 notes ...
Страница 123: ...E09 012 246 Manual S WG 124 notes ...
Страница 124: ......