1.2
Important technical warnings and guidelines
For
FAULT CODES
in this manual see
Ch. 16
on page
104
The STREBEL Domestic Hot Water systems will, for a long period, comfortably meet your requirement of hot
water of the right temperature at the right hour, provided that a few important conditions have been fulfilled
regarding the installation.
Please follow all instructions and recommendations presented in this manual by STREBEL, especially the ones
concerning the next important topics:
-
Water quality (also see § 8.1 on page 36)
A first necessary condition is the quality of the water to be heated in the DHW water heater. Three values
matter: hardness, total amount of dissolved solids and acidity. If water quality does NOT meet the require-
ments, the system may be seriously damaged.
Hardness should not exceed 205 PPM CaCO
3
(11.5°dH)
TDS (Total Dissolved Solids) should not exceed 450 PPM
Hardness and TDS together may not exceed 450 PPM
pH-value should be between 6.5 and 7.5, measured cold
The actual values can be retrieved by contacting your local water supplier.
If water quality doesn’t meet the abovementioned requirements, a water treatment installation should be in-
stalled to improve water quality to the required levels, if possible.
-
Water flow velocity and pump choice (see § 9.5 on page 51)
For a given combination of water heaters and tanks, pump choice is very important with respect to the re-
quired flow velocity.
STREBEL has done the calculations and provides a number of tables in which you can find the right pump
type suitable for your particular installation.
-
Water flow velocity and piping diameters and lengths (see § 9.4 from page 47 on)
The arguments that hold for pump choice, hold for piping design as well: all piping components added up are
giving a certain total resistance which should not exceed a critical value at which the pump cannot realize
the required flow velocity anymore.
STREBEL has done the calculations and provides a number of tables in which you can find the piping re-
quirements suitable for your particular installation.
Following the instructions and recommendations given in the referred paragraphs will highly improve the func-
tioning and considerably lengthen the life time of your STREBEL DHW system.
Furthermore, for all STREBEL appliances the next instructions and recommendations apply:
!
Never use aluminium or aluminium containing flue gas outlet
!
Always fill the siphon before commissioning the water heater
!
Always set the gas valves during commissioning the water heater, for the first time and after mainte-
nance and/or installation changes
!
Never change the parameters P2LC, P2LD, P2ML en P5BI
!
Never place an isolation valve between the safety valve and the water heater
!
In a log, keep track of all situations regarding the appliance:
what, when , by whom , what actions and/or changes, what communication has been performed
Содержание S-WG 100
Страница 13: ...E09 012 246 Manual S WG 14 3 3 S WG tanks 300 Ltr 450 Ltr ...
Страница 14: ...E09 012 246 Manual S WG 15 750 Ltr ...
Страница 33: ...E09 012 246 Manual S WG 34 7 4 Electrical schematics ...
Страница 34: ...E09 012 246 Manual S WG 35 ...
Страница 39: ...E09 012 246 Manual S WG 40 For large capacity installations more than two water heaters consult STREBEL ...
Страница 122: ...E09 012 246 Manual S WG 123 notes ...
Страница 123: ...E09 012 246 Manual S WG 124 notes ...
Страница 124: ......