STEP FIFTEEN
Figure 29
Figure 30
Figure 31
Figure 32
Long leg
at rear
Remeasure the door jambs and adjust if necessary (Figure 24).
Install the door jamb from which the door will be hung, using a
10x16 self drilling screw attached to the top channel and a rivet
attached to the bottom Z rail (Figure 29). Position the remaining
door jamb and check the Z section door stop and infill will fit
(Figure 30). Check measurements against P.A. door to ensure there
is enough room to open and close the door. Install remaining door
jamb using a 10x16 screw attached to the top channel and a rivet
attached to the bottom Z rail (Figure 29).
With both door jambs installed attach the Z section door stop and
infill using eight rivets (Figure 31). You may find it easier to attach
the Z section door stop to the infill first then attach to the door
jambs and top channel. Position the door so there is even space at
the top and bottom. Fix to the jamb using four 10x16 wafer head
screws per hinge (Figure 32). Close the door and check it opens and
closes without interference.