Miscellaneous (Blue)
The MISC field allows the audible buzzer and/or the entire Occupancy Sensor to be enabled or
disabled.
To activate/deactivate the audible buzzer or entire occupancy sensor:
Step 1. Enter Programming Mode (refer to page 16).
Step 2. Press MISC button.
Step 3. Select desired parameters:
Adjusting Scene Dimmer Levels (Green)
A Scene’s dimmer levels may be set as required.
To adjust Scene dimmer level:
Step 1. Enter Programming Mode (refer to page 16).
Step 2. Tap FIELD SELECT button until the sensor illuminates
green
.
Step 3. Tap DSCN (E) button to select the Dimmer Scenes (refer to page 16 for IR Remote
button layout).
Step 4. Tap buttons to select the following scenes:
Note:
Dimmers will go to their Last Set Scene Levels.
Step 5. Tap DIM
S
button to select "Raise Dimmer Levels". Tap DIM
T
button to select
"Lower Dimmer Levels."
Step 6. Press-Hold-Release buttons to Raise or Lower the level of the following Dimmers:
Button 1
Enable Buzzer
* Factory Default
Button 2
Disable Buzzer
Button 3
Enable Status LEDs
* When in Normal Mode
Button 4
Disable Status LEDs
Button 7
Enable Sensor
* Factory Default
Button 8
Disable Sensor
Button 0
Factory Default
* Enable Buzzer/Sensor/LEDs
Button 1
Scene 1 or On Scene (Sets Max Dimmer Levels for Daylight Harvesting)
Button 2
Scene 2 or A Scene (Sets Min Dimmer Levels for Daylight Harvesting)
Button 8
Scene 0 or Off Scene (Dimmers will always be set to Off)
Button 0
Factory Default (Scene 1)
Button 1
Dimmer 1 (Relay Pack 1 – Dimmer 1)
Button 2
Dimmer 2 (Relay Pack 2 – Dimmer 2)
Button 0
Dimmers1-2 (Master Raise/Lower – All Dimmers)