Order no.: 900312.001
V2.0
Page 9
Para-
meter
Description of function
Setting range
Values
default
Function of external switching
input E1
0: without function
1: controller on/standby
2: high-pressure alarm (see
)
3: low-pressure alarm (see
)
4: door contact (light on, fan off, see
)
5: relay function A (light 1), not active in standby
6: relay function A (light 1), regardless of standby
7: relay function B (light 2), not active in standby
8: relay function B (light 2), regardless of standby
9: relay function C (window heating),
not active in standby
10: relay function C (window heating),
regardless of standby
11: relay function D (blade scraper),
not active in standby
12: relay function D (blade scraper),
regardless of standby
13: relay function E (door frame heating),
not active in standby
14: relay function E (door frame heating),
regardless of standby
15: relay function F, not active in standby
16: relay function F, regardless of standby
17: Set1 / Set2 change-over
18: day / night change-over
19: "super-frost“ on/off (see
...
)
20: evaporator fan on permanently
21: defrosting request circuit 1
22: defrosting request circuit 2
23: control circuit 1 on/off
24: control circuit 2 on/off
0
Switching input E1 inverse / not
inverse
0: normal
1: inverse
0
Function of switching input E2
see
0
Input E2 inverse / not inverse
see
0
Function of switching input E3
see
0
Input E3 inverse / not inverse
see
0
Function of switching input E4
see
0
Input E4 inverse / not inverse
see
0
Password of parameter level
-99 ... 999
-19