Order no.: 900312.001
V2.0
Page 37
Details Intern 0
Bit Intern 0
Value=0
Value=1
R/W
15
14
Actual: Relay function „F“
off
on
R
13
Actual: Relay function „E“
off
on
R
12
Actual: Relay function „D“
off
on
R
11
Actual: Relay function „C“
off
on
R
10
Actual: Relay function „B“ (Light 2)
off
on
R
9
Actual: Relay function „A“ (Light 1)
off
on
R
8
Actual: defrosting circuit 2
off
on
R
7
Actual: day / night change-over
Day
Night
R
6
Actual: Set1 / Set2
Set1
Set2
R
5
Actual: "Humidity"
off
on
R
4
Actual: "Superfrost"
off
on
R
3
Actual: defrosting circuit 1
off
on
R
2
Actual: control circuit 2
off
on
R
1
Actual: control circuit 1
off
on
R
0
Actual: control
off
on
R
Writing to Bits that are READ ONLY will be ignored; Bits not used are reading always Zero.
Details Intern 1
c
Intern 1
Value=0
Value=1
R/W
15
14
Nominal: Relay function „F“
off
on
R
13
Nominal: Relay function „E“
off
on
R
12
Nominal: Relay function „D“
off
on
R
11
Nominal: Relay function „C“
off
on
R
10
Nominal: Relay function „B“ (Light 2)
off
on
R
9
Nominal: Relay function „A“ (Light 1)
off
on
R
8
Nominal: request defrosting control circuit 2
off
on
R
7
Nominal: day / night change-over
Day
Night
R
6
Nominal: Set1 / Set2
Set1
Set2
R
5
Nominal: " Humidity "
off
on
R
4
Nominal: "Superfrost"
off
on
R
3
Nominal: request defrosting control circuit 1
off
on
R
2
Nominal: control circuit 2
off
on
R
1
Nominal: control circuit 1
off
on
R
0
Nominal: control
off
on
R
Writing to Bits that are READ ONLY will be ignored; Bits not used are reading always Zero.