20
866-795-1586 • WWW.STONEAGETOOLS.COM
CONTROL BOX SET-UP
AIR SUPPLY AND LUBRICATOR SETTING
1. The Control Box is supplied with a twist claw style inlet coupling (Chicago style) located on the side of the FRL Assembly. Connect
a compatible compressed air line (not included) according to the Manufacturer’s instructions. If another pneumatic connection is
preferred, this fitting can be removed and any male 1/2 in NPT fitting may be used.
2. Using the pressure regulator on the FRL, adjust the operating pressure to 100 psi (0.7 MPa) for the application.
ADJUST INLINE
OILER TO FEED
1 DROP OF OIL
EVERY 30-60
SECONDS FOR
HIGH SPEED OR
CONTINUOUS
DUTY USAGE
PRESSURE
REGULATOR
AIR SUPPLY FITTING
A universal
AIR SUPPLY FITTING
(Chicago style) is
located on the FRL. Connect a compatible compressed
air line (not included) according to the manufacturer’s
instructions. If another pneumatic connection is preferred,
this fitting can be removed and any male ½ in NPT fitting
may be used.
WARNING
Maximum operating pressure is 100 psi (0.7 MPa). Never exceed 125 psi (0.86 MPa) supply pressure. Exceeding 125 psi (0.86 MPa)
supply pressure may result in injury to the Operator and/or damage to the equipment.