866-795-1586 • WWW.STONEAGETOOLS.COM
STRAP MOUNT ASSEMBLY SET-UP
FIGURE 2
FIGURE 4
FIGURE 3
BOP 058 FEMALE
POSTIONER TUBE
COMPLETE FEMALE SIDE OF STRAP MOUNT
BOP 081-6
SNOUT TUBE
SOCKET HEAD CAP
SCREWS (4)
BOP 070
HINGE CLAMP
ASSEMBLY
BOP 012
SPLASH PLATE
ASSEMBLY
ADJUSTABLE
HANDLE
BOP 070
HINGE CLAMP
ASSEMBLY
2.
Release the Adjustable Handle on the BOP 070 Hinge Clamp to access the 4 socket head cap screws. Locate the side of the BOP
030 Collet Block Assembly with 4 threaded holes. Orient the Hinge Clamp so that the hinge is on the right. Fasten the Hinge Clamp
Assembly to the Collet Block Assembly using the 4 supplied socket head cap screws.
(Figure 2)
3. Insert the BOP 058 Female Positioner Assembly into the Hinge Clamp Assembly then close the Hinge Clamp Assembly and tighten the
Adjustable Handle. The Female Positioner height can be adjusted in the open or closed position and is designed to be adjustable
based on the size of the pipe.
(Figure 3)
4. To Install the BOP 012
OPTIONAL
Splash Plate, loosen the two bolts on the collar, slide it onto the BOP 081-6 Snout Tube and hand
tighten the collar bolts when in position.