DISOCONT® Tersus (DT-9) Configuration and Operations Manual
©Schenck Process Group
9
3 Overview
This chapter explains the principle functions of the DISOCONT Tersus system used in conjunction
with a Stock coal feeder.
3.1 What is the DISOCONT Tersus/DT-9?
The DISOCONT
Tersus is a versatile family of modular weighing electronics for use with weighing
and feeding systems.
The DISOCONT
Tersus performs all weighing and processing functions required for the measuring
and feeding of bulk solids. It is designed for continuous measuring and control tasks as well as
discontinuous batching.
Used in conjunction with the specific application software for weighing and feeding tasks, the
DISOCONT
Tersus can be used in the following industries:
•
Power
•
Steel
•
Basic Materials
•
Cement
•
Food
•
Chemical.
In connection with the corresponding mechanical equipment, the following systems are supported:
•
Belt Scales
•
Weigh Feeders
•
Solids flow meters (chutes)
•
Solids flow feeders
•
Loss-in-weight, gain-in-weight feeders
•
Mass flow meters (Coriolis meters)
•
Mass flow feeders (Coriolis feeders)
•
Filling systems.
The Stock DT-9 configuration of the DISOCONT Tersus is a modified version, optimized for feeding
coal in power plant environment. There are two different versions of the DT-9. One is a completely
redesigned and updated version that is used in new installations. The second one uses the same
components and software but has been optimized for use as an upgrade to existing Stock 8085, 196,
and 196NT installations. This version uses the 196NT connectors and mounting footprint.
VCU 20103 – Designed for new installations where backwards compatibility is not required. This
version is identified by the steel mounting frame and screw type electrical connectors. A Touch
Screen HMI is always used when a VCU 20103 is installed.
VCU 20104 – Designed as a drop in replacement for the 196NT in existing installations. This version
is identified by the brown Amp style electrical connectors. The VCU 20104 can be used with either a
Touch Screen HMI or with an existing 196NT display.
3.2 Definitions
The table below explains some basic terms used in this manual.
Содержание DISOCONT Tersus DT-9
Страница 2: ......
Страница 8: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 6 ...
Страница 30: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 28 ...
Страница 40: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 38 ...
Страница 50: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 48 ...
Страница 150: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 148 ...
Страница 154: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 152 ...