DISOCONT® Tersus (DT-9) Configuration and Operations Manual
©Schenck Process Group
102
P 14.16 Actual Flow Rate (2
nd
)
Default: n/a (not used)
Options:
n/a (not used)
AO 1 thru AO 6
This parameter is used when a second analog output proportional to feedrate is required. A second
analog output card is required and is normally installed in position A10. In this case both parameter
P01.03 Analog Channel A10 and P14.16 Actual Flow Rate (2
nd
) must be set to AO 3.
Actual Flow Rate:
The Actual Flow Rate value is the feedrate that the feeder is currently delivering.
This is the default signal source for Analog Output 2 (Set by P01.04 Analog Chanel A11). The analog
output is scaled to P02.05 Nominal Flow Rate.
This parameter is normally set to n/a (not used).