STOBER
6 | Technical data
02/2019 | ID 442728.05
59
6.7
Evaluable encoders
The technical data of the evaluable encoder can be found in the following chapters.
You can use all of the encoder connections as position encoders. Master encoders may be
connected only to connection X4A or X101. The use as a motor encoder depends on which
encoder design is required by your motor and supported by the encoder connection.
6.7.1
Overview
The following table explains which connections are available for the various encoders.
Encoders
Connection
Note
EnDat 2.1 digital
X4
—
EnDat 2.2 digital
X4
—
SSI
X4
—
Incremental TTL
X4
TTL signals, differential
Incremental HTL
X4
With HT6 adapter for level conversion: HTL
signals, differential
X101
HTL signals, single-ended
X103
HTL signals, single-ended
HTL pulse and direction
X101
HTL signals, single-ended
X103
HTL signals, differential
Resolver
X4
Adjustable number of resolver poles
Tab. 51: Overview of encoder connection
6.7.2
Signal transmission
The following signal levels apply to
single-ended signal transmission
Signal level
HTL, single-ended
Low level
0 to 8 V
DC
High level
15 to 30 V
DC
The following signal levels are valid for
differential signal transmission
Signal level
Differential HTL
Differential TTL to X4
(RS422 standard)
Low level
−30 to −4.2 V
DC
−6 to −0.2 V
DC
High level
4.2 to 30 V
DC
0.2 to 6 V
DC