11 | Commissioning
STOBER
160
02/2019 | ID 442728.05
Projecting the drive controller
1.
Properties
tab:
Establish the relationship between your circuit diagram and the drive controller to be
projected in DriveControlSuite.
Reference
: Specify the reference code (equipment code) of the drive controller.
Designation
: Give the drive controller a unique name.
Version
: Version your project configuration.
Description
: If necessary specify supporting additional information such as the change
history of the project configuration.
2.
Drive controller
tab:
Select the SI6 series and the device type of the drive controller.
3.
Option modules
tab:
Safety module
: If the drive controller is part of a safety circuit, select the SR6 or SY6 safety
module.
4.
Device controller
tab:
Device controller
: Select the device controller that defines the underlying activation signals
for the drive controller.
Rx process data, Tx process data
: If you control the drive controller using a fieldbus, select
the fieldbus-specific receive and send process data.
If you operate the drive controller in combination with the SY6 safety module, select
EtherCAT Rx
and
EtherCAT Tx
for transmitting the EtherCAT process data.
If you operate the drive controller in combination with the SR6 safety module or without
safety technology (SZ6), the fieldbus connection is optional. If you do not use a fieldbus,
project
No transmission
.
Projecting the axis
1. Click on
Axis 1
.
2.
Properties
tab:
Establish the connection between your circuit diagram and the axis to be projected in
DriveControlSuite.
Reference
: Specify the reference code (equipment code) of the axis.
Designation
: Give the axis a unique name.
Version
: Version your project configuration.
Description
: If necessary specify supporting additional information such as the change
history of the project configuration.
3.
Application
tab:
Select the desired control or drive-based application.
4.
Motor
tab:
Select the motor category, the series and the type of motor operated using this axis. If you
are working with motors from third-part suppliers, enter the accompanying motor data at a
later time.
5. Repeat steps 2 – 4 for the 2nd axis (only for double-axis controllers).
6. Confirm with
OK
.