6 | Technical data
STOBER
60
02/2019 | ID 442728.05
6.7.3
X4
EnDat 2.1 digital encoders
Specification
EnDat 2.1 digital
U
2
12 V
DC
(unregulated)
I
2max
250 mA
I
2min
—
Encoder design
Single-turn and multi-turn; not suitable for linear encoders
Clock frequency
2 MHz
Max. cable length
100 m, shielded
Tab. 52: EnDat 2.1 digital specification
EnDat 2.2 digital encoders
Specification
EnDat 2.2 digital
U
2
12 V
DC
(unregulated)
I
2max
250 mA
Encoder design
Single-turn and multi-turn
Clock frequency
4 MHz
Max. cable length
100 m, shielded
Tab. 53: EnDat 2.2 digital specification