STOBER
6 | Technical data
02/2019 | ID 442728.05
43
6.3
Drive controllers
The following chapters contain specifications for the electrical data, dimensions and weight of
the drive controller.
6.3.1
Electrical data
The electrical data of the available SI6 sizes can be found in the following sections.
An explanation of the symbols used for formulas can be found in Chapter
.
6.3.1.1
Control unit
Electrical data
All types
U
1CU
24 V
DC
, +20%/−15%
I
1maxCU
0.5 A
Tab. 23: Control unit electrical data
6.3.1.2
Power unit: Size 0
Electrical data
SI6A061
SI6A062
U
1PU
280 – 800 V
DC
f
2PU
0 – 700 Hz
U
2PU
0 – max.
1PU
U
2
C
PU
180 µF
270 µF
Tab. 24: SI6 electrical data, size 0
Nominal currents up to +45 °C (in the control cabinet)
Electrical data
SI6A061
SI6A062
f
PWM,PU
4 kHz
I
2N,PU
5 A
2 × 5 A
I
2maxPU
210% for 2 s
Tab. 25: SI6 electrical data, size 0, at 4 kHz clock frequency
Electrical data
SI6A061
SI6A062
f
PWM,PU
8 kHz
I
2N,PU
4.5 A
2 × 4.5 A
I
2maxPU
250% for 2 s
Tab. 26: SI6 electrical data, size 0, at 8 kHz clock frequency