UM0891
Running the demonstration
Doc ID 16982 Rev 1
The value of IDD current in Stop mode is evaluated and displayed on LCD and the
demonstration keeps waiting until the joystick push-button is pressed. Once you press the
joystick push-button, the MCU exits the
I
DD
Stop Mode
submenu and returns to the
I
DD
Measure
menu as shown in
Note:
When the STOP mode is entered, all GPIO are configured as analog inputs and the SRAM
and the Flash memory interface clocks are stopped.
If you select the
I
DD
Sleep mode
submenu, the message shown in
is displayed.
Figure 55.
I
DD
Sleep mode menu
The value of the IDD current in Sleep mode is evaluated and displayed on LCD and the
demonstration keeps waiting until the joystick push-button is pressed. Once the joystick
push-button has been pressed, the MCU exits the
I
DD
Sleep Mode
submenu and returns to
the IDD Measure mode menu as shown in
.
When the Sleep mode is entered, the SRAM and the Flash interface clocks are stopped.
Note:
Make sure that the JP8 jumper is installed in the I
DD
position before running the I
DD
measurement demonstration.
2.7.7 Thermometer
The STM32F100VB microcontroller has two embedded I
2
C peripherals that can be
connected to any device supporting the I
2
C protocol including the system management bus
(SMBus) mode. An STLM75 (or a compatible device) I
2
C temperature sensor is mounted on
the STM32100B-EVAL board and used to get instantaneous external temperature (-55°C to
+125°C) .
When the
Thermometer
submenu is selected, the message shown in
displayed on the LCD.
Sleep Mode
IDD: xxx,xxx mA
To exit press
Joystick