UM2027
Mains
voltage dips and interruptions
DocID029048 Rev 1
25/37
Standard
Application
Test type
%
residual
voltage
Number
of cycles
Required
criteria by
standard
STEVAL-
IHT008V1
result
61000-2-1
environments
40
10
1
/12
2
C
B
70
25
1
/30
2
C
A
Interruptions
0
250
1
/300
2
C
B
EN55024
Information
technology
equipment
< 5
0.5
B
A
70
25
C
A
< 5
250
C
B
EN55014-
2
appliances,
electric tools,
etc.
0
0.5
C
A
40
10
C
B
70
50
C
A