Safety
3
Safety tests
– Observe the guidelines regarding inspec-
tion work on industrial trucks as specified by
FEM 4.004.
The operating company is responsible for
ensuring that any defects are remedied
without delay.
– Contact your service centre.
NOTE
Observe the national regulations of your
country!
Insulation testing
The insulation of the truck must have sufficient
insulation resistance. For this reason, insula-
tion testing in accordance with DIN EN 1175
and DIN 43539, VDE 0117 and VDE 0510
must be conducted at least once a year as part
of the FEM testing.
The insulation testing results must be at least
the test values given in the following two
tables.
– For insulation testing, contact the autho-
rised service centre.
The exact procedure for this insulation testing
is described in the workshop manual for this
truck.
NOTE
The truck's electrical system and drive batte-
ries must be checked separately.
Test values for the drive battery
Component
Recommended
test voltage
Measurements
Nominal voltage
U
Batt
Test values
50 VDC
24 V
> 1200
100 VDC
48 V
> 2400
Battery
100 VDC
Batt+
Batt-
Battery tray
80 V
> 4000
.
172780 EN - 06/2017
27
Содержание R 07-25
Страница 2: ......
Страница 4: ......
Страница 11: ...1 Foreword ...
Страница 18: ...1 Foreword Environmental considerations 8 172780 EN 06 2017 ...
Страница 19: ...2 Introduction ...
Страница 28: ...2 Introduction Residual risk 18 172780 EN 06 2017 ...
Страница 29: ...3 Safety ...
Страница 45: ...4 Overviews ...
Страница 59: ...5 Operation ...
Страница 134: ...5 Operation Trailer and load 4 Fold down the side panel 4 using both hands 124 172780 EN 06 2017 ...
Страница 163: ...6 Maintenance ...
Страница 212: ...6 Maintenance Maintenance intervals 202 172780 EN 06 2017 ...
Страница 217: ...7 Technical data ...
Страница 240: ...7 Technical data Towed load for the front coupling tow tractors with short and long wheelbases 230 172780 EN 06 2017 ...
Страница 244: ......
Страница 245: ......
Страница 246: ...STILL GmbH 172780 EN 06 2017 ...