![STIEBEL ELTRON HSBC 300 cool Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/stiebel-eltron/hsbc-300-cool/hsbc-300-cool_operation-and-installation_1376858058.webp)
INSTALLATIoN
Specification
58
| HSBC 300 cool | HSBC 300 L cool www.stiebel-eltron.com
HSBC 300 cool
HSBC 300 L cool
Weights
Weight, full
kg
641
639
Weight, empty
kg
250
248
Further details
HSBC 300 cool
HSBC 300 L cool
236686
238826
Maximum altitude for installation
m
2000
2000
16.3 Accessories
Pipe assembly RBS-SBC
rBS-SBC
238827
Connections
Cold water connection
mm
22
DHW connection
mm
22
DHW circulation connection
mm
12
Versions
Suitable for
...SBC 300 cool / plus and 300 L cool / plus
Pump assembly HSBC 3-HKM
HSBC 3-HKM
238825
Connections
Heating circuit connection
mm
22
Auxiliary heating element HSBC 3-HE
HSBC 3-He
200025
Electrical data
Connected load ~ 230 V
kW
2
Rated voltage
V
230
Phases
1/N/PE
Frequency
Hz
50
Application limits
Temperature setting range
°C
35-80
Max. permissible pressure
MPa
1.0
Minimum cylinder diameter
mm
500
Minimum cylinder volume
l
150
Dimensions
Flange external diameter
mm
140
Immersion depth
mm
480
Torque
Nm
45
Weights
Weight
kg
2