INSTALLATIoN
Installation
44
| HSBC 300 cool | HSBC 300 L cool www.stiebel-eltron.com
D
00000
80
38
5
f
f
Insert the temperature sensor into the sensor well provided.
Electrical connection HSBC 3-HKM
MA19
M
1~
M
1~
XD03.3
MA11
L
N
BT13
MKP (X2.4)
6
5
MISCHER (X2.14)
N
2
L
1
4
3
2
N
LA
LZ
L
M
1~
N
7
8
9
BK BU
BN
BK BU GNYE
D
00000
81
76
1
f
f
Wire up the heating circuit pump and 3-way mixer (see chap-
ter "Installation / Electrical connection / Control voltage").
10.2.3 If necessary, install an HSBC 3-HE auxiliary heating
element as an accessory
D
00000
80
38
6
2
1
1 Blank flange
2 Insulation segment
f
f
Remove the insulation segment in front of the flange plate.
f
f
Remove the blank flange.
90
°
1
3
5
D
00000
80
53
9
1
1 Earthing contact PE
f
f
Move the auxiliary heating element into the correct instal-
lation position. Use the position of the earthing contact as a
guide.
D
00000
80
38
7
f
f
Install the auxiliary heating element. Observe the tight-
ening torque (see chapter "Installation / Specification /