Reset

LED display

The green LED display        - operating OK - is shining. It goes out
in case of:
- mains or battery failure
- malfunction of the line monitoring of the connected drives,
automatic detectors or SHE manual call points.

The yellow LED display       - malfunction - lights up when a fault is
pending: Line break in the smoke alarm line, SHE-button-line as
well as motor circuit or missing or fault line end.
Battery faulty = error message in the compact SHE control centre
and in the manual call points.
Network faulty = error message in the compact SHE control centre
only.

If any malfunction is indicated the malfunction has to be
eleminated immediately. The perfect function of the
system is not longer guaranteed.

The red LED display       - SHE activation - is shining in case of:
manual or automatic SHE activation.

- 4 linear drives 24 V DC with integrated electronic power cut-off, or
- 4 chain motors with limit switches (overall power consumption of

all motors connected: max. 4 A)

- 10 SHE manual call points RBH/3A...
- 10 automatic detectors with 2-wire-technology (smoke detectors

and/or detectors of heat)

- 10 external ventilation switches “open” / ”stop” / ”closed” (e.g.

type LTA 25)

- 1 wind and rain detector WRM24V or 1 rain detector RM24V
- ower supply 24 V AC / 100 mA for a wind and rain detector or

ain detector

- 1 display “On” 24 V AC / max. 50 mA
- 1 onnection: Isolated change-over contact 30 V AC / max. 5 A,

switches when SHE-triggered

p

r

c

Funktionsbeschreibung

Description of operating

LED-Anzeigen

Die grüne LED-Anzeige        - Betrieb OK - leuchtet. Sie erlischt bei:
- Netz- oder Akkuausfall
- Störung der Leitungsüberwachung zu den Antrieben, RWA-

Bedienstellen oder automatischen Meldern.

Die gelbe LED-Anzeige       - Störung - leuchtet:
eine Störung steht an: Leitungsbruch in der Rauchmelder-Linie,
RWA-Taster-Linie sowie im Motorkreis oder fehlender bzw. defekter
Linienabschluss.
Akku defekt = Störungsmeldungen in der Zentrale und RWA-
Bedienstellen.
Netz defekt = Störungsmeldung nur in der Zentrale.

In diesen Fällen muss unbedingt sofort die Störung
beseitigt werden. Eine reibungslose Funktion der
Anlage ist nicht mehr gewährleistet.

Die rote LED-Anzeige       - RWA ausgelöst - leuchtet:
nach Drücken der AUF-Taste in einer RWA-Bedienstelle bzw. im
Bedienfeld der Steuerzentrale und nach dem Auslösen durch
automatische Melder.

- 4 Linearantriebe 24 V DC mit eigener elektronischer Last-

abschaltung oder

- 4 Kettenantriebe mit Endschaltern (gesamte Stromaufnahme aller

angeschlossenen Antriebe max. 4 A)

- 10 RWA-Bedienstellen RBH/3A...
- 10 automatische Melder in 2-Leiter-Technik (Rauch- und/oder

Wärmemelder)

- 10 externe Lüftungstaster AUF/STOP/ZU (z.B.: Typ LTA 25)
- 1 Wind- und Regenmelder WRM24V oder 1 Regenmelder RM24V
- Spannungsversorgung 24 V AC / 100 mA für einen Wind- und

Regenmelder oder Regenmelder

- 1 Anzeige “Auf” 24V AC / max. 50 mA

1 Anschluss: potentialfreier Wechselkontakt 30 V AC / max. 5 A,

schaltet bei RWA-Auslösung

-

Anschlussmöglichkeiten

Possible connections

OK

!

OK

!

L    N    PE

1 2 3 4 5 6 7 8 9 10111213

1415161718192021222324

Sicherung Netz T1A

fuse net T1A

AKKU /
sw rot

battery

black red

Sicherung AKKU T4A

fuse battery T4A

Sicherung Trafo T4A

fuse transformer T4A

LED grün Netz
Betrieb OK

LED green net
operating ok

Taste Zu

switch closed

Taste Reset
Rauchmelder

switch reset smoke detector

LED grün Auf

LED green open

LED rot: RWA-Auslösung/LED red SHE activation

LED gelb: Störung Motorkreis/LED yellow malfunction motor circuit

LED gelb: Störung Netz/AKKU/LED yellow malfunction mains/battery

LED gelb: Störung RWA-Taster-Linie/LED yellow malfunction man. call points

LED gelb: Störung Rauchmelder-Linie/LED yellow malfunction smoke detectors

Lage der LED-Anzeige

Legende RBH/3A /

legend RBH/3A

switch SHE open

switch SHE closed

LED SHE open

LED operating ok

LED malfunction

Taster RWA-AUF /
Taster RWA-ZU /

LED RWA-AUF /
LED Betrieb OK /
LED Störung /

OK

!

rote/red

Rauchabzug

Smoke vent

OK

!

rote/red

6

Motor

RM/

S D

RWA-

230 V

Batt.

Taster

M

F-Trafo T 4A L

F-Netz / F mains
T1A

F-Batt.
T 4A L

Netz / mains

Batt.
2 x 12 V 2 Ah

ZU
Closed

Auf / Open

D
GB

Содержание MZ 4A-1RG-1LG

Страница 1: ...d function of the connected SHE manual call point Opening and closing for daily ventilation Smoke vent flaps as dome lights folding skylights or windows with 24 V DC linear drives or chain motors hereafter referred to only as windows eletromechanical openings in stairways Funktion Tägliches Lüften 1 RWA Gruppe 1 Lüftungsgruppe Stromversorgung 230 V AC 24 V DC Notstromakkus und optische Störmeldung...

Страница 2: ...automatic opening and closing of the stated types of windows For further application please contact the manufacturer Required mounting material is to be adapted to the frame and the corresponding load and is to be completed if necessary Any supplied mounting material is only part of the required amount If the equipment is employed in smoke heat extraction systems in short SHE they must be checked ...

Страница 3: ...gregate dauerhaft vor Wasser und Schmutz Safety instructions Routing of cables and electrical connections only to be done by a qualified electrician Power supply leads 230 V AC to be fused separately by the customer Keep power supply leads sheathed until the mains terminal DIN and VDE regulations to be observed for the installation VDE 0100 Setting up of high voltage installations up to 1000 V VDE...

Страница 4: ... oder Wärmemelder Wind und Regenmelder WRM 24V oder Regenmelder RM24V Compact SHE control centre Mains supply Junction box Smoke vent Vent switch automatic detector with 2 wire technology as smoke detector and or heat detector Wind and rain detector WRM 24V or rain detector RM 24V 24 V DC linear drive or chain motor with power cut off overall max 4A 1 2 3 4 5 6 7 8 Rauchabzug Smoke vent 1 4 m 1 2 ...

Страница 5: ... opening windows Smoke heat extraction closing windows Autom activation in case of fire smoke alarm Funktionsbeschreibung Description of operating Manuelle Auslösung bei Feuer Brand Alarm Tägliches Lüften Rauchabzug Fenster öffnen Rauchabzug Fenster schließen kein Fenster öffnen Fenster schließen Schließen mit Wind Regenmelder Hinweis rote AUF Taste in einer RWA Bedienstelle drücken Fenster werden...

Страница 6: ...ienstellen Netz defekt Störungsmeldung nur in der Zentrale In diesen Fällen muss unbedingt sofort die Störung beseitigt werden Eine reibungslose Funktion der Anlage ist nicht mehr gewährleistet Die rote LED Anzeige RWA ausgelöst leuchtet nach Drücken der AUF Taste in einer RWA Bedienstelle bzw im Bedienfeld der Steuerzentrale und nach dem Auslösen durch automatische Melder 4 Linearantriebe 24 V DC...

Страница 7: ...tung VENT Rauchabzug Smoke heat extraction The specified types of cables can possibly be used for flush mounting This is however to be agreed with the site management or if necessary with the local fire protection authorities We recommend for surface mounting fireproof cables with maintain functin E90 E30 according to DIN 4112 For E90 E30 the cable cross sections must be adapted to conform with th...

Страница 8: ...im letzten oder einzigen Melder einklemmen nach beiliegender Montage und Bedienungsanleitung Dabei beachten die Abzweigdosen müssen so platziert werden dass die Anschlussleitungen der Antriebe ohne Verlängerung direkt angeschlossen werden können Als Linienabschluss zwei Überwachungsdioden in der Anschlussdose des letzten oder einzigen Antriebes einklemmen Antriebe niemals ohne Lastabschaltung betr...

Страница 9: ...en Line termination Nip the 10kOhm terminal resistor between terminal 1 and 3 in the last or unique SHE manual call point blau blue braun brown ein Lüftungs taster Auf Zu gemeinsam Stop one vent switch open closed together Stop ein Lüftungs taster mit Sicht anzeige LTA 20 one vent switch with visual display LTA 20 ein Antrieb mit Lastabschaltung gesamt max 4A Stromaufnahme one drive with power cut...

Страница 10: ... Fire Alarm System FAS BMA FAS 2 A S Ö 1 Anzeige Auf 24V max 50mA display Open 24V max 50mA Alarmweiterschaltung potentialfreier Wechsel kontakt 30V max 5A schaltet bei RWA Auslösung Alarm further switching isolated change over contact switches for SHE Triggering A Ö S Anschlussklemmen in der Steuerzentrale terminals in the control centre 10 Endwiderstand 10kOhm End resistor 10kOhm Enwiderstand 10...

Страница 11: ...ießen vollständig Mit Netzspannung mit Akku Funktionstest Probelauf Lüftungstaster RWA Bedienstelle OK OK OK Without mains voltage and without battery With mains voltage without battery With mains voltage and battery Check LED Display in compact control centre and all SHE manual call points Vent switch SHE manual call point Check all parts mechanically and electrically for fully tightened screw co...

Страница 12: ...aster mit umgekehrter Funktion Lüftungstaster ohne Funktion d örmeldung steht an OK OK Test emergency power supply Remove mains protection in the switchboard the green LED Running OK goes out the yellow LED fault mains battery lights up push ON button in the vent switch no reaction in the window push SHE OPEN button open the windows the red LED display SHE activation lights up the green LED Runnin...

Страница 13: ...structions of the connected components must imperatively be observed Technische Daten Technical data Betriebsspannung Netzanschluss Systemspannung Notstromakku s 2 x 12V 2Ah mit Tief Notstrombereitschaft d Zurücksetzen Reset der RWA Auslösung Leistungsabgabe zu den Antrieben Leitungsüberwachun Sichtanzeige optisch Betrieb OK RWA ausgelöst Störung Anschlussart nach extern Lüftung Auf Netz Betrieb S...

Страница 14: ...erhöhter Blendrahmen 82 mm Standardblendrahmen Measures of wall box h x w x d Iinternal dimension heigth 235 measures of niche 310 x 330 x required space for wall box 295 x 310 installation measure of niche depth at least 68 mm from 68 to 81 5 mm increased facing frame 82 mm facing frame standard Einbau Unter Putz Die Zentrale mit geeigneten Dübeln und Schrauben durch die Maueranker oder die Befes...

Отзывы: