![Stern 350805 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/stern/350805/350805_installation-and-maintenance-manual_1375276009.webp)
14
15
SETTInGS AdjUSTmEnT
SETTInGS AdjUSTmEnT
DeTeCTiOn RAnGe:
This faucet was supplied with a self
adjusting sensor. The ideal detection range for the specific
location will be set automatically.
Only if necessary, use the remote control to adjust the sensor
range as follows:
Press the RANGE button. Wait until a quick flashing of the red light
in the sensor eye is perceived. Then, press + to increase the range
and – to reduce it. Every push will increase or decrease one level.
Note: Once you have changed the detection range with the remote control,
the distance will be remembered by the sensor, even if the power source is
disconnected. To get back to the self adjustment mode, use the ADJ button only.
ENTRANCE TO THE SELF ADJUSTMENT MODE: Check that no
objects are in front of the sensor. Press the ADJ button. Once
a quick flashing of the red light of the sensor eye is perceived,
remove your hand holding the remote control and move away
from the sensor area. The ideal sensor range for the specific
location will be set automatically. Once the self adjustment has
taken place, the solenoid valve will be opened and closed for 1
second as an indication that the ideal sensor range was set and
the product is ready for use.
SECURITY TIME: The Security time, prevents continuous running
of water due to reflections or vandalism. By default, if the sensor
is covered for more than 90 seconds the water flow will shut
automatically. To resume regular operation any obstruction must
be removed.
Press the SEC button. Wait until a quick flashing of the red light in
the sensor eye is perceived. Then, press + to increase the security
time and – to reduce it.
Adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control, hold
the remote control straight in front of the sensor in a distance of about 6-8” (15-20cm).
Choose the function you want to adjust by pressing once on one of the function buttons.
After pressing once on a specific function button, a quick flashing of the red light at the
front of the sensor will occur. At this stage, you can change the setting by pressing the
(+) or the (-) buttons, every push will increase or decrease one level. After finishing the
adjustment, turn the water supply back on.
DETECTION
RANGE
DELAY IN TIME
SECURITY TIME
COMFORT FLUSH
DELAY OUT TIME
TEMPORARY OFF
FUNCTION
RESET
SELF ADJUSTMENT
MODE
HYGIENE FLUSH