Stern 350805 Скачать руководство пользователя страница 9

14

15

SETTInGS AdjUSTmEnT

SETTInGS AdjUSTmEnT

DeTeCTiOn RAnGe:

 

This faucet was supplied with a self 

adjusting sensor. The ideal detection range for the specific 

location will be set automatically. 
Only if necessary, use the remote control to adjust the sensor 

range as follows:
Press the RANGE button. Wait until a quick flashing of the red light 

in the sensor eye is perceived. Then, press + to increase the range 

and – to reduce it. Every push will increase or decrease one level. 

Note: Once you have changed the detection range with the remote control, 

the distance will be remembered by the sensor, even if the power source is 

disconnected. To get back to the self adjustment mode, use the ADJ button only.

ENTRANCE TO THE SELF ADJUSTMENT MODE:  Check that no 

objects are in front of the sensor. Press the ADJ button. Once 

a quick flashing of the red light of the sensor eye is perceived, 

remove your hand holding the remote control and move away 

from the sensor area. The ideal sensor range for the specific 

location will be set automatically. Once the self adjustment has 

taken place, the solenoid valve will be opened and closed for 1 

second as an indication that the ideal sensor range was set and 

the product is ready for use. 

SECURITY TIME: The Security time, prevents continuous running 

of water due to reflections or vandalism. By default, if the sensor 

is covered for more than 90 seconds the water flow will shut 

automatically. To resume regular operation any obstruction must 

be removed.
Press the SEC button. Wait until a quick flashing of the red light in 

the sensor eye is perceived. Then, press + to increase the security 

time and – to reduce it.

Adjusting the settings with the remote control

If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control, hold 

the remote control straight in front of the sensor in a distance of about 6-8” (15-20cm). 

Choose the function you want to adjust by pressing once on one of the function buttons. 

After pressing once on a specific function button, a quick flashing of the red light at the 

front of the sensor will occur. At this stage, you can change the setting by pressing the 

(+) or the (-) buttons, every push will increase or decrease one level. After finishing the 

adjustment, turn the water supply back on. 

DETECTION 

RANGE 

DELAY IN TIME

SECURITY TIME 

COMFORT FLUSH

DELAY OUT TIME 

TEMPORARY OFF 

FUNCTION 

RESET

SELF ADJUSTMENT 

MODE

HYGIENE FLUSH

Содержание 350805

Страница 1: ...Wall mounted electronic faucet with mixer TUBULAR 1000 SERIES Tubular 1000 B Tubular 1000 E Tubular 1000 B Box Tubular 1000 E Box I n s t a l l a t i o n a n d m a i n t e n a n c e g u i d e...

Страница 2: ...right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials and other specifications of its products and to eith...

Страница 3: ...len key 1x Allen key Power splitter Power splitter Temporary protective cover Spout and attachments incl electronic unit Tubular base Wall rosette M4x6 screw Rigid pipes not supplied Box mounting pack...

Страница 4: ...cordance with applicable codes and regulations STEP 1 INSTALLING THE FAUCET 1 Shut off the water supply 2 Drill a hole 28 to 29 mm where you want to install the spout of the faucet and a small hole ju...

Страница 5: ...cable coming from the electronic unit that leads to the solenoid valves to the power splitter Important This product includes a self adjusting sensor The ideal sensor range for the specific location w...

Страница 6: ...over Step 3 Connecting the power source 1a For Tubular 1000 B Connect the cable coming from the electronic unit in the Tubular base leading to the power source to the battery box from the electronic u...

Страница 7: ...in wall level b Cut the box mud guard cover wherever required by the installation 9 Assemble the wall rosette over the Tubular base and secure it using the 2 screws provided 10 Connect the cables fro...

Страница 8: ...ge for the specific location will be set automatically OBJECT Before proceeding check that no objects are in front of the sensor besides the washbasin Now remove the protective sticker that covers the...

Страница 9: ...second as an indication that the ideal sensor range was set and the product is ready for use Security time The Security time prevents continuous running of water due to reflections or vandalism By def...

Страница 10: ...lows Press the IN button Wait until a quick flashing of the red light in the sensor eye is perceived Then press to increase the delay in time and to reduce it Delay OUT time This button allows modifyi...

Страница 11: ...ng water supplies f Make sure that there is no water leakage 2 For Tubular 1000 B Box and Tubular 1000 E Box a Release the screws at the panel and remove it Turn off the regulating valve b Disassemble...

Страница 12: ...return to normal operation remove any blockage In this case the water flow will stop anyway after 90 seconds because of the security time SOLUTION CAUSE INDICATOR PROBLEM Replace battery Low battery 1...

Страница 13: ...08 17 015350800 D 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Отзывы: