TEchnIcAL dATA

IndEX

1              TECHNICAL DATA

2 -3 

PACK CONTENTS

4  

PRE-INSTALLATION INFORMATION

5-13          FAUCET INSTALLATION

14-16 

SETTINGS ADJUSTMENT

17 

BATTERY REPLACEMENT INSTRUCTIONS

18 MAINTENANCE

  

     FILTERS CLEANING INSTRUCTIONS

 

     CARE AND CLEANING OF CHROME AND SPECIAL FINISHES

19 

SPARE PARTS 

20 

LIMITED WARRANTY

21 

TROUBLESHOOTING

TUBULAR 1000

Wall mounted electronic  

Faucet With a mixer to  

adjust the temperature 

Power supply for battery versions: 

9V battery or 6 x 1.5 V AA batteries

Power supply for electricity versions: 

9V transformer 

Recommended water pressure:

0.5-8.0 bar (7-116 PSI)
With water pressure of more than 8 bars, 

use a pressure reducing valve for  

reduction

Sensor range: 

Self adjusting

Minimum sensor range: 

80 mm

Maximum sensor range: 

300 mm

Security time:

90 seconds. Can be reduced with the remote 

control

Hot water temperature:

Max. 70

º

C

the information in this document reflects products at the date of printing. stern engineering ltd  reserves the right,  subject to all applicable laws, at any time, at its sole discretion, and 

without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the forgoing 

from the market. all information in this document is provided “as is” without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of mer-

chantability, fitness for a particular purpose, or non-infringement. stern engineering ltd  assumes no responsibility for errors or omissions in the information presented in this document. 

in no event shall stern engineering ltd  be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising out of or in connection with 

the use or performance of this information. the tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of stern engineer-

ing ltd or other third parties and you are not permitted to use them without the prior written consent of stern engineering ltd  or such third party as may own them.

Содержание 350805

Страница 1: ...Wall mounted electronic faucet with mixer TUBULAR 1000 SERIES Tubular 1000 B Tubular 1000 E Tubular 1000 B Box Tubular 1000 E Box I n s t a l l a t i o n a n d m a i n t e n a n c e g u i d e...

Страница 2: ...right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials and other specifications of its products and to eith...

Страница 3: ...len key 1x Allen key Power splitter Power splitter Temporary protective cover Spout and attachments incl electronic unit Tubular base Wall rosette M4x6 screw Rigid pipes not supplied Box mounting pack...

Страница 4: ...cordance with applicable codes and regulations STEP 1 INSTALLING THE FAUCET 1 Shut off the water supply 2 Drill a hole 28 to 29 mm where you want to install the spout of the faucet and a small hole ju...

Страница 5: ...cable coming from the electronic unit that leads to the solenoid valves to the power splitter Important This product includes a self adjusting sensor The ideal sensor range for the specific location w...

Страница 6: ...over Step 3 Connecting the power source 1a For Tubular 1000 B Connect the cable coming from the electronic unit in the Tubular base leading to the power source to the battery box from the electronic u...

Страница 7: ...in wall level b Cut the box mud guard cover wherever required by the installation 9 Assemble the wall rosette over the Tubular base and secure it using the 2 screws provided 10 Connect the cables fro...

Страница 8: ...ge for the specific location will be set automatically OBJECT Before proceeding check that no objects are in front of the sensor besides the washbasin Now remove the protective sticker that covers the...

Страница 9: ...second as an indication that the ideal sensor range was set and the product is ready for use Security time The Security time prevents continuous running of water due to reflections or vandalism By def...

Страница 10: ...lows Press the IN button Wait until a quick flashing of the red light in the sensor eye is perceived Then press to increase the delay in time and to reduce it Delay OUT time This button allows modifyi...

Страница 11: ...ng water supplies f Make sure that there is no water leakage 2 For Tubular 1000 B Box and Tubular 1000 E Box a Release the screws at the panel and remove it Turn off the regulating valve b Disassemble...

Страница 12: ...return to normal operation remove any blockage In this case the water flow will stop anyway after 90 seconds because of the security time SOLUTION CAUSE INDICATOR PROBLEM Replace battery Low battery 1...

Страница 13: ...08 17 015350800 D 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Отзывы: