![Stern 350805 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/stern/350805/350805_installation-and-maintenance-manual_1375276011.webp)
18
19
mAInTEnAncE
TUBULAR
1000
SEALS AND SCREWS KIT
07210113
10-PACK SA SENSOR KIT TUBULAR 1000 B
07220254
10-PACK SA SENSOR KIT TUBULAR 1000 E
07220255
8-PACK SOLENOID BS-HOUSING KIT
07221119
8-PACK SOLENOID BS-HOUSING KIT FOR USA
07221122
10-PACK SOLENOID VALVE KIT
07232000
10-PACK DIAPHRAGM
04500048
MIxER HANDLE KIT
07260007
BATTERY BOx
06530092
12-PACK 9V TRANSFORMER
06540002
TUBULAR
1000
BOX
SEALS AND SCREWS KIT
07210076
PANEL KIT
07040119
10-PACK SA SENSOR KIT TUBULAR 1000 B BOx
07220281
10-PACK SA SENSOR KIT TUBULAR 1000 E BOx
07220298
8-PACK SOLENOID BS-HOUSING KIT
07201103
NIPPLE KIT
07246002
10-PACK DIAPHRAGM
04500048
FILTER
08530011
MIxER HANDLE KIT
07260007
BATTERY BOx
06530100
12-PACK 9V TRANSFORMER
06540002
fiLTeR CLeAninG inSTRUCTiOnS
These models are provided with stainless steel filters preventing foreign particles to enter
the lines. It is recommended to clean the filters every six (6) month. If the water flow has
decreased, this may be because the filters are clogged. The filters can be cleaned as
follows:
1. for Tubular
1000
B and Tubular
1000
e:
a. Shut-off the water shut off valve.
b. Disconnect the water supply pipes from the adapters and disassemble the filters.
c. Wash the filters under running water.
d. Reassemble the parts.
e. Restore the incoming water supplies.
f. Make sure that there is no water leakage.
2. for Tubular
1000
B Box and Tubular
1000
e Box:
a. Release the screws at the panel and remove it. Turn off the regulating valve.
b. Disassemble the solenoid valves by opening the nuts.
c. Remove the filters and wash them under running water.
d. Reassemble the filters.
e. Reassemble the solenoid valves.
f. Turn on the regulating valve and adjust the flow capacity.
g. Make sure that there is no water leakage. Reassemble the wall cover panel
SOLenOiD vALve SeRviCinG
The
solenoid valve diaphragm requires periodical cleaning every six (6) month.
Remove the diaphragm from the solenoid valve and examine it for dirt. in case it is dirty
or clogged, wash it under running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic
solenoid valves.
CARe AnD CLeAninG Of CHROMe AnD SPeCiAL finiSHeS
DO nOT
use steel wool or cleansing agents containing alcohol, acid, abrasives, or the
like. Use of any prohibited cleaning or maintenance products or substances could
damage the surface of the faucet. For surface cleaning of faucet us
OnLy
soap and water,
then wipe dry with clean cloth or towel. When cleaning bathroom tile, the faucets should
be protected from any splattering of harsh cleansers.
If system chemical disinfection is practiced, chlorine can be used (calculated
chlorine concentration of 50mg/l maximum in water per one hour dwell time) at
service interval frequency.