Appendix A
Hard Keys
Home (Index Keys)
Set Point
Process
Heat Low
Heat
High
SP1
###
Main Set Pt.
175
175
ALO
###
Alarm Low
-100
AHI
###
Alarm High
200
Set Point
Process
Heat Low
Heat
High
SYS
On/OFF
System On or Off (Standby)
On
Prg
run/HLd
note 1
Programmer Run/Hold
ti
###
note 3
Program Segment Time remaining
#ti
###
note 3
Program Segment Time
#SP
###
note 3
Program Segment Set Point
tun
Tune choice
PID
PID
SLF
Self Tuning
Lrn
YES/No
Start Learn
dFa
OFF, 1 to 7
Damping factor 1=less, 7 = more
ratio rate to reset
3
3
Pid
Manual PID tuning
PbH
1 to 5000
Proportional Band 1 (deg or counts)
14
14
PbC
1 to 5000
Proportional Band 2 (deg or counts)
20
10
rES
0 to 999.9
Reset time in sec
1.5
1.5
OFS
0 to 99.9
Manual reset value in percent
OFF
OFF
rtE
0 to 99.99
Rate time in minutes
0.05
0.05
SLO
Slow response process
nor
Normal response process
FAS
Fast response process
FPC
0 to 100
Fuzzy intensity in percent 0 = off
Impact fuzzy logic has on process
50
50
Fbd
1 to 400
Fuzzy Band in deg. or counts = to PBH
14
14
FrC
0 to 99.9
Fuzzy rate of change in deg. or counts per
second
2.5
2.5
PEA
###
Peak PV, ENTER to reset to present PV
UAL
###
Valley PV, ENTER to reset to present PV
2SP
###
Auxiliary Set Pt.
0
0
tc
###
Note 4
T/C Monitor Temp
FAL
0 to 100
Note 4
Flow Alarm Low
0
0
FAH
0 to 100
Note 4
Flow Alarm High
100
100
AUt
OFF, 1 to 5
Auto vent cycle OFF, 1 to 5 min.
1.0
OFF
HiH
On/OFF/AUt
High Heat On/ Off/Auto
AUt
AUt