Tech Support:
www.steppir.com/support
Tel: 425.891.6134
Page 71
NOTE: When wiring the control ca-
ble from the coax switch to the
connector junction box, the green
wire is not used. Be sure to trim the
green wire on each end of the con-
trol cable and tape over it to avoid
potential electrical shorts.
J5 PLUG
LOCATED INSIDE PN 70-3001-01
ANTENNA SWITCH HOUSING
If the 80m dipole option was purchased, terminal lug “S” and “C” on J6 (inside connector junction box) will have
2 wires being inserted into each lug. Be sure to twist these into a “pair” before inserting into the respective ter-
minal lug (these lugs are highlighted in yellow).
Start your wiring at J6 plug inside the connector box; route the wiring from there to the antenna switch box
and/or 80m dipole box. 5 ft of control wire is provided, which can either be coiled up or trimmed to size. Be
sure to route the cable BEFORE cutting it to be sure you have enough. To avoid confusion in wiring, it is recom-
mended that the wires of the 4 conductor control cable that are not used are trimmed back from the connec-
tions. Wires used going to J5 plug are: shield, black, white and red. Green is not used. For optional 80m di-
pole wires used are: shield, black and green. Red and white are not used. The factory installed jumper should
be left untouched! Do not tin the ends of the wires.
S
C
R3
R2
R1
OPTIONAL
J6 PLUG
LOCATED INSIDE PN 70-3002-01
80M DIPOLE ANTENNA SWITCH
HOUSING
J6 PLUG
LOCATED INSIDE PN 70-2038
CONNECTOR JUNCTION BOX
S
COM
R4
R3
R2
5
1
R
ed
W
hi
te
Bla
ck
S
hie
ld
Shield
Green
Black
Not used
FACTORY
INSTALLED
JUMPER
CHAPTER ELEVEN
SECTION 11.1
WIRING THE CONNECTOR JUNCTION BOX (continued)
CONNECT CONTROL CABLE FROM COAX SWITCH TO JUNCTION BOX
FIG. 11.16