Tech Support:
www.steppir.com/support
Tel: 425.891.6134
Page 68
CHAPTER ELEVEN
SECTION 11.1
WIRING THE CONNECTOR JUNCTION BOX (continued)
WIRING THE CONNECTOR JUNCTION BOX
Every electrical function is routed through the connector junction box. There are six junction connec-
tions, each of which consists of a female header that is attached to the circuit board inside the box, and
a male plug for each as shown in
figure 11.10
. When we ship the connector junction box, the plugs will
already be attached to the female headers and will need to be removed for wiring as shown in
figure
11.11
.
Figure 11.12
shows the connector junction box with the plugs removed.
The table in
figure 11.13
identifies each of the connector junctions inside the connector junction box and
provides notes for each connection. Note: The wiring drawings for
Figure 11.14, 11.15 and 11.16
men-
tioned below, will follow this page.
Figure 11.14
shows detailed wiring information for each of the connector junctions inside the box. Be
sure to dip each of the exposed wires into the included connector protector before inserting into the ter-
minal strip inside the junction box
. Figure 11.15
shows in detail the diagram for connecting the 16 wire
control cable to the P1 and P2 plugs inside the junction box.
Figure 11.16
shows in detail the diagram
for connecting the control cable from the coax switch to the junction box. When connecting the wiring
for J6 (coax switch housing), the green wire will need to be trimmed and taped in the same manner
covered in
Chapter Ten.
ID
Cable Routed
From:
Figure 11.13
Installation Notes
J1
REFLECTOR
4 wire control cable, plus shield wire (all wires used).
J2
DRIVEN
6 wire control cable, plus shield wire (all wires used).
J3
DIRECTOR 1
6 wire control cable, plus shield wire (all wires used).
J4
DIRECTOR 3
4 wire control cable, plus shield (all wires used)
J5
DIRECTOR 2
6 wire control cable, plus shield (all wires used)
P1
CONTROL CABLE
FROM HAM SHACK
The first 13 wires of the 24 the conductor cable used (Pins 1-13), plus
the shield wire.
P2
CONTROL CABLE
FROM HAM SHACK
The remaining 11 wires of the 24 conductor cable used (Pins 15-24).
Pin 25 is
NOT USED
.
J6
COAX SWITCH
HOUSING
4 wire control cable; the green wire needs to be trimmed and taped;
R1 is NOT USED. 3 total wires used, plus shield wire.
FIG. 11.10
FIG. 11.12
FIG. 11.11