MANUAL NCBM 01 Revision 14 11/06/2021
STEM S.r.l. via della Meccanica, 2 I-27010 Cura Carpignano- Pavia Italia Tel. +39 0382 583011 Fax +39 0382 583058 www.stemsrl.it [email protected]
Subject to change without notice, no responsibility will be taken for every detail. © STEM S.r.l.
FIG. 3 Bucher I-valve signals
2.5 Signalling Hydraulic mode
Using the function
LED functionality
of the user interface SW is possible select the led options.
NORMAL FUNCTIONALITY HYDRO
MONITOR / NOMONITOR
BUCHER I-VALVE
LED
(OPZ1)
(OPZ2)
LED1(GREEN)
Up(On/Off)
Valve V1
OFF
LED2 (GREEN)
Down (On/Off)
Valve V2
OFF
LED3 ((GREEN)
High speed (On/Off)
POWER OK
Blink if travel low / On if travel high
LED4 (GREEN)
Doors (On/Off)
Doors (On/Off)
SMA signal, on if high
LED5 (GREEN)
Lower floor (On/Off)
Lower floor (On/Off)
Time verification pending, On until SMA signal change
the state
ALL (RED)
Alarm (Off)
Alarm (Off)
Alarm (Off)
TAB. 1 Led Meaning in normal functionality monitor / nomonitor / I-Valve configuration
TEST PENDING
TEST IN PROGRESS
LED
(OPZ1)
(OPZ2)
(OPZ1)
(OPZ2)
LED1
(Green)
Up (On/Off)
Valve V1 (O1 out
On/Off)
Off
Valve V1 (O1 out On/Off)
LED2
(Green)
Down (On/Off)
Valve V2(O2 out
On/Off)
Off
Valve V2(O2 out On/Off)
LED3
(Green)
Test pending (Led blink)
Test pending (Led
blink)
Test pending (Led blink)
Test pending (Led blink)
LED4
(Green)
Doors (On= open
Off=closed)
Doors (On= open
Off=closed)
Doors (On= open
Off=closed)
Doors (On= open
Off=closed)
LED5
(Green)
Lower floor (On=at floor
/Off =not at floor)
Lower floor (On=at
floor /Off =not at
floor)
Test in progress (led blink)
Test in progress (led blink)
ALL (Red)
Alarm (Off)
Alarm (Off)
Alarm(Off)
Alarm (Off)
TAB. 2 Led Meaning during test monitoring pending or in execution