Page 29
16400-7802 GBY REV G
Inside Corner
A = Combustible 24” (609.6mm)
= Non-combustible 12” (304.8mm)
F = Combustible 6” (152mm)
= Non-combustible 6” (152mm)
Balcony
with perpendicular side wall
Outside Corner
Recessed Location
Balcony
with no side wall
G = Combustible
= Non-combustible
H = Combustible
= Non-combustible
I = Combustible
= Non-combustible 12” (305mm)
C = Clearance from corner in
recessed location
= Combustible 24” (609.6mm)
= Non-combustible 12“ (304.8mm)
D = Minimum width for back wall
of a recessed location
= Combustible 64” (1,625.6mm)
= Non-combustible 40” (1,016mm)
E = Maximum depth of 48“ (1,219mm)
for recessed location
24” (609.6mm)
12” (304.8mm)
24” (609.6mm)
24” (609.6mm)
12” (304.8mm)
IMPORTANT:
All dimensions are from the
edge of the cap.
Figure 8M
M. HORIZONTAL TERMINATION VENT CAP LOCATION & CLEARANCES
8 - VENTING