![Stellar Hearth Products 3BY-24GL Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/stellar-hearth-products/3by-24gl/3by-24gl_installation-and-operating-manual_1371591023.webp)
Page 23
16400-7802 GBY REV G
Figure 7
CAUTION: Consult the local and national installation codes to assure adequate combustion and ventilation air is available.
NOTE: Flame height and appearance will vary depending upon venting configuration and type of fuel used.
Venting requirements apply to both Natural and Propane gas.
STOP: MAINTAIN ALL CLEARANCES AS STATED IN THIS INSTALLATION MANUAL.
8 - VENTING
A. APPROVED VENTING
Model #
DESCRIPTION
B-VENT
OUTSIDE
AIR
STANDARD
POWERVENT
IN-LINE
POWERVENTV
3'
ANY HEIGHT
8"
10"
RS012
RSIF160
4'
ANY HEIGHT
8”
10”
RS012
RSIF160
5'
ANY HEIGHT
8”
10”
RS012
RSIF160
6'
ANY HEIGHT
10”
10”
RS014
RSIF180
7'
ANY HEIGHT
10”
10”
RS014
RSIF180
8'
ANY HEIGHT
10"
12"
RS014
RSIF180
B. POWERVENT SUPPLY VOLTAGE
POWERVENT MODEL NUMBER
VAC
AMP
H/P
RS012 (3', 4', & 5' Models)
120
1.2
1/9
RS014 (6', 7' & 8' Models)
120
1.4
1/7
RSIF160 (3', 4', & 5' Models)
120
2.9
3/7
RSIF180 (6', 7' & 8' Models)
120
5.3
13/16
C. SYSTEM SUPPLY VOLTAGE
POWERVENT MODEL NUMBER
VAC
AMPS
RS012 (3', 4', & 5' Models)
120
3.2
RS014 (6', 7' & 8' Models)
120
3.4
RSIF160 (3', 4', & 5' Models)
120
4.9
RSIF180 (6', 7' & 8' Models)
120
7.3
Figure 8A
*Amperage listed is the maximum required for the appliance with all options.
Refer to the vent systems manufacturer's installation manual for complete installation instructions.
Installation must conform with the venting requirements and restrictions as outlined in this manual.
SEE CHART ABOVE FOR SIZE diameter B-Type Venting that must be used. UL/CSA approved
B-Vent only. DO NOT
decrease the vent size.
Vent runs are approved for up to 110 feet with quantity of eleven 90 degree elbows.
Vent runs may also contain a downward component.
The downward component may
be a maximum of 6 feet plus the distance to the center line of the elbow. See Figure 8A.1.
This will be about 87" for 8" diameter pipe and 92" for 10" diameter pipe.
Due to natural buoyancy of flue gas products, venting downward increases restriction.
Every inch of vertical drop counts as triple inches subtracted off the total vent run.
Example: a maximum drop of 92" means the total allowed vent run is decreased by 276" (23')
Once a downward component has been utilized, the vent cannot go upwards again,
Moisture may get trapped in the vent pipe.
Important: Be sure to do your own calculations based on the center line dimension
given from the pipe manufacture you are using for your installation.
NOTE: All pipe and elbow joints must be sealed. This includes the longitudinal seam on the pipe.
High Temp RTV Silicone and/or foil tape MUST be used on each joint/seam.
Failure to do so may cause lack of vacuum and may not trigger the vacuum switch.
Содержание 3BY-24GL
Страница 2: ...INS_CUST UL REV E Page 2...
Страница 35: ...Page 35 16400 7802 GBY REV G...
Страница 51: ...Page 51 16400 7802 GBY REV G...
Страница 52: ...INS_CUST UL REV E Page 52...