![Stellar Hearth Products 3BY-24GL Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/stellar-hearth-products/3by-24gl/3by-24gl_installation-and-operating-manual_1371591014.webp)
INS_CUST UL REV E
Page 14
4 - PREPARE THE FIREPLACE
C. SHIPPING SUPPORT BRACKETS
D. THREADED RODS
The hood shall be supported at specific locations using 1/4-20 UNC threaded rods.
Qty 2 threaded rods are required in the front and back left hand corner
glass-to-glass intersections (I & J)
All other locations are optional if additional support is needed.
MODEL
QTY
Additional
I
J
K
REQ
OPT
INCHES
MM
INCHES
MM
INCHES
MM
3' BY
2
2
5
127
6-3/8
162
NA
NA
4' BY
2
2
5
127
8-7/8
225
NA
NA
5' BY
2
2
5
127
11-7/8
302
NA
NA
6' BY
2
6
5
127
6-7/8
175
26-7/8
683
7' BY
2
6
5
127
6-7/8
175
32-7/8
835
8' BY
2
6
5
127
6-7/8
175
38-7/8
987
Figure 4C
Temporary Shipping Support Bracket
1.
Install the threaded rods in the appropriate locations for I, J & K
as noted below in Framing - A.
2.
Level the fireplace.
3.
Ensure fireplace is fully supported and leveled and then remove
support brackets.
CAUTION! RISK OF INJURY!
DO NOT
remove support brackets until fireplace is fully supported
and level.
J
I
REQUIRED
REQUIRED
OPTIONAL
OPTIONAL
Figure 4D.1 - 3' 4' & 5' Models
Top View
I
J
K
REQUIRED
REQUIRED
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
Figure 4D.2 - 6', 7' & 8' Models
Top View
The Galaxy BAY Series requires 2 threaded rods to be placed at the glass-to-glass intersections.
Placement of the required threaded rods is at the I & J intersection at the front left and back BAYs notated as REQUIRED I & J locations.
Additional locations are provided if your installation needs more support notated as OPTIONAL I, J & K locations.
Once the required threaded rods are in place and the the hood fully supported, the temporary support brackets may be taken off.
See Page 11 for threaded rod installation option.
The hood must be supported at specific locations using 1/4-20 UNC threaded rods.
Temporary support brackets are put in place for shipping and installation support and must stay in place until fireplace hood is fully supported.